2Manual No. 016-0159-823 7IntroductionCalculate the Meter Cal ValueNo calculation of the Meter Cal value is necessary, since the flow meter calibration value is stamped on the tagattached to each flow meter. Locate this number and write it down for future reference when programming theconsole.Calculate the Valve Cal ValueThe Valve Cal figure is used to control the response time of the control valve motor to the change in thevehicle’s speed. After operating the system, this number may be refined. The initial recommended controlvalve values are:• C-SD (standard valve) = 2123• C-FC (fast-close valve) = 743• C-F (fast valve) = 743• C-P (PWM valve) = 43• C-PC (PWM close valve) = 43FIGURE 3. Valve Calibration DefinitionsDigit Description Range Range DefinitionValve BacklashControls the time of the first correction pulseafter a change in correction direction isdetected (INC to DEC, or DEC to INC)1 - 9 1 = Short Pulse9 = Long PulseValve SpeedControls the response time of the control valvemotor. Caution: Running the control valvetoo fast will cause the system to oscillate.Refer tospecific valveRefer to specificvalveC-SD Valve 1 - 9 1 = Slow9 = FastC-F and C-FC Valve 0 - 9 0 = Fast9 = SlowC-P and C-PC Valve 0 - 9 0 = Slow9 = FastC-SD Valve C-F or C-FC Valve C-P or C-PC Valve