Chapter 534 SCS 660 & 660M Serial Interface for Granular Applications Installation & Service ManualSystem FeaturesData MenuPressing the DATA MENU button displays the menu options by name and the default setting. Use the arrowkeys to scroll through the menu options.Menu Option FunctionPRINT FIELD BEGINSends data through the serial port to the attached printer (optional - not supplied byRaven) to Print Field Begin and Print Field End pages. Pressing CE will toggle betweenthe two pages.1. Press ENTER to print the Print Field Begin. The display will now showPRINT FIELD END.2. PRESS ENTER to print the Print Field End.ALARM ONTurns the audible alarms on and off for the Vol/Minute Rate Fault, Volume/Area RateAlarm, Low Tank Fault, Right Shaft Fault, Left Shaft Fault, and Bin Level Fault features.Pressing CE will toggle between Alarm On and Alarm Off.DISPLAY SMOOTHINGONTurns display smoothing on and off. Display Smoothing On adjusts the console todisplay the target rate when the actual rate is within 10% of the target rate. DisplaySmoothing Off displays the actual target rate. Pressing CE will toggle between the twosettings.FAN RPM 0 Displays the fan’s RPM in the console’s display.SHAFT 1 FAULT OFF Turns the left shaft fault detector on and off. When the fault detector is On, the alarmsounds and the display flashes “SHAFT 1” if the left shaft should be rotating, but is not.SHAFT 2 FAULT OFF Turns the right shaft fault detector on and off. When the fault detector is On, the alarmsounds and the display flashes “SHAFT 2” if the right shaft should be rotating, but is not.BIN LEVEL FAULT OFFTurns the bin level fault detector on and off. When the fault detector is turned On, thealarm sounds and the display flashes “BIN LEVEL” if the granular level drops below thebin level sensor.FAN CAL 0 Displays and allows the entry of the fan calibration value.RATE CHANGEALARM ONTurns the rate change alarm on and off. When the rate change alarm is turned on, analarm emits 4 long beeps when the Rate 1 cal value is changed via the serial port usinga valid change request data string.GPS FILE REF 1 This application is not currently used in the SCS 660 system.GPS INACTIVE This application is not currently used in the SCS 660 system.FIELD REF 0 Allows the user to enter up to a four-digit number to represent a field. Field reference isincluded in the field begin and field end pages and the data logger time/date string.BAUD RATE 9600 Used in the data logging mode. The baud rate option is 1200 - 9600 baud.DATA LOG TRIGGERVALUE 0Used in the data logging mode. The trigger determines how often the actual rate datastring is sent to the serial port. The trigger may either be in feet/meters or seconds. Thedefault value is set to zero. This value must be changed to a number ranging from 1 -9999, or the data logger feature will not work.DATA LOG TRIGGERUNITS FEETUsed in the data logging mode. The trigger may either be in feet/meters or seconds.Pressing CE will toggle between the FEET (METER) and SEC.DATA LOG OFFTurns the data logger on and off.Note: The trigger value must be set to a value other than zero in order totoggle DATA LOG to ON.