Wuhan Raycus Fiber Laser Technologies Co., LtdUser Guide RFL-A2000D-3000D Ver.1.0133.3 Cooling RequirementsTable 2: Cooling RequirementsParameter Unit RFL-A2000D RFL-A2500D RFL-A3000DCoolingCapabilitykW ≥4 ≥5 ≥6Minimum Flow L/min 25Maximum InletPressureBar 7 7 7Pipe InnerDiametermm 19Water temperature setting:Summer (ambient temperature higher than 30℃): 29±0.5℃;Winter (ambient temperature lower than 30℃): 25±0.5℃.Purified water should be used. In order to prevent mildew growing, we recommend to addalcohol about 10% of total volume. The cooling system should equip with filter. Check and cleanthe filter every six months.If the product is used in an environment that ambient temperature is between -10 ℃ and0℃, we recommend to use 30% alcohol, and replace it every two months.If the product is used in an environment that ambient temperature is below -10℃, you mustuse chiller with both heating and cooling functions, and keep it in full-time operation.When connecting to the laser for the first time, ensure that the flow and return connectionsare correct.If you will not use the laser for a long time, water should be emptied from the laser, andthen block inlet and outlet. Failure to do so may lead to permanent equipment damage.CAUTION: Please set the water temperature in strict accordance with therequirements above. Too low temperature may lead to condensation in theLaser module and the output head. This can cause serious damage to theequipment.