8540573 • 16/09/2016 • Rev.20 37TECHNICAL DATAGENERAL DATASafety category 4Response time ms 30Reset automatic or manual selectablePower supply Vdc 24 20%ConnectionsEmitter M12 – 5 pins (male)Receiver M12 – 8 pins (male)Receiver M23 – 19 pins (male)* Muting sensors M12 – 5 pins (female)Protection rating IP 65Max. length ofelectrical connections m 100Dimensions light curtain section mm 50 x 60Operating temperature °C -10 55Max operative humidity % 95Safety outputs 2 PNP auto-controlled – 500 mA @ 24 Vdcwith short-circuit, overload, reversal of polarity protectionMax. output current mA 500Max. capacitive load F 2,2Max. off-state voltage V < 1Max. resistance of connections betweenOSSDs and the loads Ohm < 25Light curtain status andweak signal outputs PNP – 100 mA at 24 VdcMax. consumption W 3 (Emitter) 6 (Receiver)* Max current to Muting sensors(only MI models) mA 100* Muting lamp output 24Vdc / 0,5 5 W* Response time onMuting signals (sensors) ms 100* Muting max. time-out models ML -ML S2 - MT - MI with 2 sensors 30 sec or 90 min (selectable)* Muting max. time-outmodels MI with 4 sensors - MT S4 30 sec or excludible (selectable)* Override max. time-out min 15 (renewable)Light curtain lifetime 20 yearsSafety levelType 4 IEC 61496-1:2004IEC 61496-2:2006SIL 3 IEC 61508:1998SILCL 3 IEC 62061:2005PL e - Cat.4 ISO 13849-1 : 2006* Specifications applicable only to models with Muting functionMI SERIESHeights of guarded areas mm 310 ÷ 1810 for light curtains with a resolution of 40 and 90 mm310 ÷ 1210 for light curtains with a resolution of 30 mmResolution of light curtains fordetecting upper or lower limbs mm 30 – 40 - 90Number of beams of light curtains fordetection of body in access control 2 – 3 – 4Operating range Low / High m 0 ÷ 6 / 1 ÷ 16Muting system two-way with 2 or 4 sensors with max. concurrent time of 4 sectwo-way sequential with 4 sensorsMuting sensors external with relay or PNP output