E33-10 FPI Direct Vent Gas Insert | 31|31installationWIRING DIAGRAMThis heater does not require a 120V A.C. supplyfor operation. However, a 120V A.C. powersupply is needed for the fan/blower operation.WARNING: Electrical Grounding InstructionsThis appliance is equipped with a three pronged(grounding) plug for your protection against shockhazard and should be plugged directly into aproperly grounded three-prong receptacle. Do notcut or remove the grounding prong from this plug.Caution: Ensure that thewires do not touch any hotsurfaces and are away fromsharp edges.CAUTION: Label all wires priorto disconnection when servicingcontrols. Wiring errors can causeimproper and dangerous operation.ENGLISHREMOTETPTHTPTH GreenWhiteRedBlack(+) (-)9GroundNeutralLiveBlackBlackRedMinimum ConvectionAir Temp. SwitchON OFFRotary SpeedControl120V AC60 HzGreenGroundFanLockwasherFangroundPowercordgroundwireStarwasherNutNut#8 Ground LugStarwasherDCSpark BoxToElectrodeToElectrodeThermostat(Optional)(Millivolt)OptionalWall ThermostatA wall thermostat may be installed if desired,connect the wires as per the wiring Diagram.Use table to determine the maximum wire length.Note: Preferable if the thermostat isinstalled on an interior wall.Regency ® offers an optional programmablethermostat but any 250-750 millivolt rated non-anticipator type thermostat that is CSA, ULC orUL approved may be used.Thermostat Wire TableRecommended Maximum Lead Length(Two-Wire) When Using WallThermostat (CP-2 System)Wire Size Max. Length14 GA. 50 Ft.16 GA. 32 Ft.18 GA. 20 Ft.20 GA. 12 Ft.22 GA. 9 Ft.CAUTIONDo not wire millivoltwall thermostat wiresto 120V wire.NOTE: When the wall thermostat is connected, the remote control transmitterand all of its features are now disabled.