Regency Horizon™ HZ42STE Gas Fireplace 25INSTALLATIONVERTICAL TERMINATIONSRIGID PIPE 4" X 6-5/8"The minimum components required for a basic verticaltermination are:1 Vertical Termination Cap1 45 o Elbow1 Rigid Pipe Adaptor (510-994)1 Ceiling Firestop1 Flashing1 Storm Collar1 Length of pipe to suit wall thickness(see chart)When using Rigid Vent other thanSimpson Dura-Vent, 3 screws must beused to secure rigid pipe to adaptor.This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunctionwith Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Directand Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor isdeemed acceptable and does not affect the Intertek WHI listing of components.WARNING:Do not combine venting components from different venting systems.However use of the the AstroCap TM and FPI Riser is acceptable with all systems.The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent ® Direct Vent,American Metal Products Ameri Vent Direct Vent, Security Secure Vent ®, ICC Excel, Selkirk Direct-Temp. AstroCap TM is a proprietary trademark of FPIFireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.Roof Pitch Minimum Vent HeightFeet Metersflat to 7/12 2 0.61over 7/12 to 8/12 2 0.61over 8/12 to 9/12 2 0.61over 9/12 to 10/12 2.5 0.76over 10/12 to 11/12 3.25 0.99over 11/12 to 12/12 4 1.22over 12/12 to 14/12 5 1.52over 14/12 to 16/12 6 1.83over 16/12 to 18/12 7 2.13over 18/12 to 20/12 7.5 2.29over 20/12 to 21/12 8 2.44Galvanized pipe is desirable above the roofline due to its higher corrosionresistance. Continue to add pipe sections through the flashing until theheight of the vent cap meets the minimum height requirements specified inDia. 4 or local codes. Note that for steep roof pitches, the vertical heightmust be increased. A poor draft, or down drafting can result from highwind conditions near big trees or adjoining roof lines, in these cases,increasing the vent height may solve the problem.Vertical TerminalStorm CollarFlashingCeiling FirestopPipeLengthRigid Pipe Adapter45 Elbowo