11Regency IG35 Gas Inbuilt FireplaceConversion Kit #486-967 for NG to ULPGTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!Conversion Kit 486-967 Contains:Qty. Part # Description1 904-345 Burner Orifice #531 918-273 Red "ULPG" label1 918-272 Label "Converted to ULPG"1 918-542 Instruction Sheet1) Shut off the gas supply and unplug the powercord.2) Remove the front door.3) Remove logs.4) Remove the rear log tray by removing the 2screws. (Log tray must be rotated to clearthe burner.)Control BoxCoverAntenna13) Remove the control box cover by undoing the3 screws. Maneuver through antenna.Jumper LocationJumper14) Remove the jumper using a plier.5) Remove the grate.6) Remove the burner and adjust the aerationsetting to 15 mm fully open.7) Remove burner orifice with a 1/2" wrenchand discard. Use a wrench to hold on to theelbow behind the orifice.8) Reinstall new burner orifice ULPG stamped#53 and tighten.9) Stick the conversion label "This unit hasbeen converted to ULPG" over top of theserial number decal.10) Replace the yellow "NG" label with the red"ULPG" label.11) Carefully pull out the control box.NOTE: The control box is held in place withvelcro.12) Remove the heat shield from the controlbox by removing the 2 screws.15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2.Heat ShieldINSTALLATION