8 3 /4 "(222mm)14 3 /8 " (365mm)Fan Grille(Not Supplied)Fan BezelFan HousingStrain ReliefGroundCover PlateFan HousingFigure 8: Wiring fan.e) Secure the cover plate to the back of the fan hous-ing with screwsf) Secure the service wires to the strain relieff) For wiring options see Figure 9.8. Attach the 5” Aluminum Flex Vent to the FireplaceVent Duct Collar with sheet metal screws or a ventstrap and run the vent to the Fan Housing Vent DuctCollar. The Fan Housing Vent Duct can be installedthrough the rear or the bottom of the Fan Housingas shown in Figure 10.IMPORTANT: Maintain a minimum of 2” (51mm)clearance between the flex lines and combustiblematerials.Optional Note: An 8ft (2.4m) 5” Aluminum Flex Ventis provided. An extra 5” aluminum flex run can beadded using a coupling provided by the installer. Anextra 12’ in length can be added making the total run20’, which is the maximum allowable.9. Attach the fan bezel to the fan cut out and securethe fan bezel to the wall board with screws.10. Cover the cut out with a fan grille.When installed, the Power Vent Kit, must be electricallygrounded in accordance with local codes or, in theabsence of local codes, with the National ElectricalCode, ANSI/NFPA 70, or the Canadian ElectricalCode, CSA C22.1.Fan HousingVent Duct CollarFireplace VentDuct Collar5" AluminumFlex VentFigure 9: Fan wiring options.Figure 11: Install fan bezel & grille.Figure 10: Optional install with two (2) heat distribution kits.WARNING: Electrical Grounding InstructionsThis appliance is equipped with a three-prong (grounding) plug for your pro-tection against shock hazard and should be plugged directly into a properlygrounded three-prong receptacle. Do not cut or remove the grounding prongfrom this plug.Periodic examination of venting systems should be done by a qualified agency.8” X 14” grille is required-purchased separately.28 | HZ965/L965 Gas Fireplace|28installation