www.support4service.de Valve Control 2a (VC2a), Rev. 1.3 Page 4 / 132. Performance characteristicsThe unit is equipped with two independent channels, each provided with a 6- and a 3-poleoutput socket. The performance characteristics described below apply to each channel.a. Supply voltageThe valve tester Valve Control VC 2a is supplied with 115 / 230 VAC.b. Output voltagesFor energizing of valves through the 6-pole output socket, the VC 2a provides the voltages- +24VDC for maximal 4 A and- +/- 15 VDC for maximal 2 A.Additional simple valves can be operated by adaptor „A“ with +24 VDC / 4 A.At the 3-pole output socket a voltage of +24 VDC for maximal 1,5 A is provided.c. Voltage and current set pointsThe following set point ranges are available on the 6-pole output socket of VC 2a:1. 0 .- 5 V2. 0 - 10 V3. +/- 5V4. +/- 10 V5. +/- 10 mA an 500 Ohm6. +/- 20 mA an 300 Ohm7. +/- 40 mA an 200 Ohm8. +/- 400 mA an 25 Ohm9. +/- 1200 mA an 5,4 Ohm10. 0 - 10 mA an 500 Ohm11. 0 - 20 mA an 500 Ohm12. 4 - 20 mA an 500 Ohm13. 0 - 40 mA an 300 Ohm14. 0 - 400 mA an 25 Ohm15. 0 - 800 mA an 20 Ohm16. 0 -1600 mA an 5,4 Ohm17. 0 - 2400 mA an 5,4 Ohm18. 0 - 4000 mA an 4 Ohm