Index revision : C - November 2017 37 7030• Step 4: Insert the end fitting into the high voltage cable and screw on manually, then witha 6 mm open-ended spanner. Tighten fully.• Step 5: Lubrication• Coat the high voltage cable endfitting with a layer of dielectriclubricant.• Step 6: Insert high voltage cable intoplacebo and push it fully in.• Step 7: Coat placebo thread withIS401 adhesive and screw the cable-securing adapter onto placebo.6.9.2. Assembling / disassembling the internal resistor in the placebo6.9.2.1. Disassembly• Step 1: Unscrew high voltage cable stopper (item 1) with a flathead screwdriver.• Step 2: Remove HV contact disc (item 2) and spring (item 3).• Step 3: Unscrew HV contact housing (item 4).• Step 4: Unscrew resistor (item 6) assembly with its two springs (item 5) with a flatheadscrewdriver.6.9.2.2. Reassembly• Step 1: Coat all components with a thin layer of dielectric lubricant.• Step 2: Assemble resistor (item 6) with its two springs (item 5), then screw into the placebousing the special tool (P/N 900002675).• Stage 3: Screw on HV contact housing (item 4).• Step 4: Place spring and HV contact disc into the placebo.• Step 5: Screw in high voltage cable stopper.Step 5Step 7Step 6DES037031 2 3 4 5 6 5