NEW ROYAL 05 TROUBLESHOOTINGSaeco International Group Rev. 01 Page / 075.1. Test modeTo enter Test Mode:- Switch on the machine.- Press the four function keys in the sequence indicated below (SX3, SX2, SX4, SX1) before theinitialization bar is completed.Entry into Test Mode results in a screen divided intosections, as illustrated in the diagram below01MENU OK ESCSX1 DX1SX2 DX2SX3 SX4 DX3 DX4BUTTON MAIN FUNCTION SECONDARY FUNCTIONSX1 Select ground/pre-ground Menu access (hold down)SX2 EspressoSX3 Coffee OKSX4 Access to Special Menu ESCDX1 Clean cycle Scroll menu upDX2 Cappuccino Scroll menu downDX3 Latte macchiatoDX4 Entry to Stand-ByThe sectors highlighted in yellow on the following screens represent the various loads that can beactivated by pressing the keys indicated in each sector.This load is deactivated by pressing the same key once more.The sectors highlighted in green provide information on the sensor status.Other conditions in which a load can be automatically deactivated are:- If a work cycle is defined and ends (e.g., coffee grinder or brewing unit).- A time-out is reached (e.g.: 5 sec for the boiler test).The symbols can be activated with keys SX4 and DX1 and are used to navigate the Testmode.TITLESX1INFO1INFO5 INFO6 INFO7INFO2 INFO3 INFO4DX2 DX3 DX4SX2 SX3PartsGuru.com