7hologramserial nr.sw ver.www.safeline-group.com1 2 34 5 67 8 9* 0 #SafeLine MX3 +MX3+ v.2.02 ENOverviewWiring diagram,output 1, 2 andexternal buttonUse CABLE13 to connect SafeLine MX3+ withexternal accessories. Output 1 and 2 can beconfigured independently.Requires that the outputis configured for thecorresponding function.Please refer to the Parameterlist (*88*) or the app formore information.0 = Pictogram (Output 1 - yellow, Output 2 -green)1 = Activate with DTMF 8/9 (Output 1 - DTMF8,Output 2 – DTMF9)2 = System failure3 = Emergency bellE.g. *88*13# configures output 1 for anemergency bell.Pictogram yellow(Output 1, Configuration code 0)The output is activated at the following events:- Input for emergency bell is activated.- Input for emergency bell is set active at a certain time.The output is deactivated at the following events:- Distress input deactivated before set time.- Active alarm ended.- Reset button (#) is pressed.Pictogram green(Output 2, Configuration code 0)The output is activated at the following events:- Voice communication activated.- Incoming call connected.The output is deactivated at the following events:- Outgoing call ended/timeout/cancelled.- Incoming call ended/timeout/cancelled.- Reset button (#) is pressed.OutputsThe two outputs can be configured independentlywith a number of functions. The configurationis performed via SafeLine Pro or with theconfiguration code *88*XY#, where X specifiesoutput 1 or 2 and Y specifies the function:Output 2Output 1