p. 16p.2530EnglishENGLISHLED indicationfront panelContinuous green Mains power supply OK.Flashing red (400/400 ms) Battery operated, with power to the emergency light.Continuous red Battery operated, no power to the emergency light.Fig 3.1 - LED 1 indicates the power supply statusLight off No active alarm/battery OK.Rapidly flashing yellow (200/200 ms) Active alarm not reset.Flashing red (400/400 ms) Battery check in progress.Continuous red Battery test failure/no battery connected.Fig 3.1 - LED 2 indicates active alarm and battery conditionFlashing green (100/100 ms) Fire mode activated.Flashing green (400/400 ms) Call connection in progress.Slowly flashing green (200/4600 ms) Telephone line connected. / GSM network OK.Continuous green Call connected.Flashing yellow (100/100 ms) Incoming call.Flashing red (400/400 ms) No telephone line connected. / Searching for GSM network.Continuous red No SIM card (when using GSM).Fig 3.1 - LED 3 indicates the phone line's statusPress for 3 sec Show GSM signal strength (see table below).Press 3 times Start a self test (battery + bus initialization).Press once Resets an active alarm. Aborts calls in progress.Press 5 sec - release SL6+ turns off. NOTE: refers to battery powered onlyFig 3.1 - Reset buttonStoring of two different telephone numbers, one to be answered byP100 code and the other one with voice.ConfigurationexampleIf at any time you need to startover, use the factory resetcommand *99*1#.Please refer to the fullconfiguration setup in the“Parameter list” as these aremerely examples.1. Start configuration:0 02. 1st phone number:* 1 1 * 1 2 3 4 5 6 7 8 #3. 2nd phone number:* 1 2 * 2 3 4 5 6 7 8 9 #4. Call type 1st number:* 2 1 * 0 # - Example: Answered with P100 code.5. Call type 2st number:* 2 2 * 1 # - Example: Answered as voice call.6. Alarm button delay:* 8 7 * 0 3 # - Example: 3 seconds delay.7. End configuration:* 0 0 * #[DOCSxxxx] SL6 Quick guide 201811.indd 30 2019-02-21 15:10