T-Max® Manager/Plus and T-Max®3A/F/I User’s Guide Page 371) Place the Jumper on Pins 1&2 on JP99 on the back of the T-Max®3A/F/I (See Figure C).2) Attach the two wires on the T-Max® Sentry™ to the terminal block labeled “Sensor” onthe T-Max®3A/F/I (refer to Figure C, Section 12.3 and Figure E, Section 12.5).3) Find a load carrying wire on your tanning bed (not the wire connected to the relay on the T-Max®3A/F/I). Run that wire through the center of the T-Max® Sentry™ (refer to Figure D,Section 12.5).If your tanning bed draws less than 10 AMPS, wrap the wire around the T-Max®Sentry™ one time (refer to Figure E, Section 12.6).If the bed remains on after the session time has expired, or if the bed did not energize after asession has started, an error will appear on the T-Max®3A/F/I. An audible alarm will alsosound.Set Parameter 4 on the T-Max®3A/F/I to a 1 (refer to Section 5.2.2 f you are the T-Max®Mgr/Plus for manual operation or Section 6.3.5 if you are using ADNET).Refer to Section 13 for troubleshooting tips.11.5 High Pressure (Single-Side) BedsThe T-Max®3A/F/I has an alarm that will beep for 10 seconds half way through the sessioninforming the customer to turn over. If you are not using a T-Max® Mgr/Plus, this optionmust be enabled at the factory.If you are using a computer, refer to Section 6.3.5 and set parameter 2 to a 1 for the bed thatyou are enabling the Mid-Session Flip alarm. If you are using the T-Max® Mgr/Plusmanually, refer to Section 5.2.2 on how to send parameters manually.11.5.1 Installing External Speaker (Optional)If the speaker on the T-Max®3A/F/I is not loud enough, a T-Max® Speaker that connects tothe T-Max®3A/F/I is available. To install the T-Max® Speaker do the following. See FigureC, Section 12.3 for J6 location and J99 and J100 locations and jumper positions.Note: The External speaker has nothing to do with the intercom. It is only used to providea louder beep for the beeper on the T-Max® 3A/F/I.1) Connect the cable on the T-Max® Speaker to the J6 on the back of the T-Max®3A/F/I2) Place the Jumper on J100 to pins 2 and 3 on the back of the T-Max®3A/F/I3) Set Parameter 20 to a 1 (Refer to Section 5.2.2 if you are using the T-Max® Mgr/ Plusmanually, Section 6.3.5 if you want to use ADNET or Section 8.2 if you want to enable thisfunction at the T-Max®3A/F/I).11.6 Connecting a Remote Push Button to the T-Max®3A/F/I (Optional)A T-Max®3A/F/I can be used to control another T-Max®3A/F/I. This is ideal for smallsalons that are not using a T-Max® Mgr. Two T-Max®3A/F/Is are required for remote singlebed control.