Salus RT510BC+ Quick Manual
Also see for RT510BC+: Quick guideQuick guide
TEST / PAIRINGSELECT+HrSETi Once paired please close theboiler control panel.The LED will start flashing red.TEST / PAIRING+HrSELECT SETRXBC605 InstallationRXBC605 Wiring TerminalsRXBC605136254Remove the front panel from the boiler.Do not remove boiler loop.Replace the front panel ensuring a good seal is made.Connect the electrical plug.Pull out the mechanical timer.Push fit boiler control into housing.7 Power up the boiler and check the correct operation.Quick GuideRT510BC+Always isolate the AC Mains supply before installing or working on any componentsthat require 230 VAC 50Hz supply.RT510BC+ (Thermostat) Button FunctionsIntroductionThe RT510BC+ thermostat will switch your heating system on or off, as needed, in accordancewith the time and temperature set by you. It can be used with the RXBC605 integral plug-in RFboiler control. The RF boiler control is a direct replacement for the basic time clock or blankingplate usually supplied with the boiler. Installing the RF boiler control takes minutes. Onceinstalled, you will benefit from all the control features of the RT510BC+ thermostat.868.0-868.6MHz; <13dBmSafety InformationUse in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnectyour device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, andinstallation must comply with the guidance, standards and regulations applicable to the city, country orstate where the product is installed. Failure to comply with the relevant standards could lead to prosecution.Product ComplianceThis product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity isavailable on www.saluslegal.com+HrSELECTSELECTSETSET+++Key Function1. Press once to activate Frost Mode2. Press for 3 seconds in order to activate Holiday ModePress once to activate/deactivate Boost functionPress once to enter/exit Permanent Override functionIncrease buttonDecrease buttonSelect the clock or programme settingsPress to confirm your settings1. Press once to enter/exit in Test Mode2. Press for 3 seconds to enter/exit Pairing ModePress the buttons for 3 seconds to enter Installer ModePress the buttons for 3 seconds to enter Clock SettingsBox contentQuick Guide 2 x AA AlkalineBatteries 2 x Fixing ScrewsRT510BC+ Desk StandTEST / PAIRINGSELECT+HrSETi Once paired please close theboiler control panel.The LED will start flashing red.TEST / PAIRING+HrSELECT SETRXBC605 InstallationRXBC605 Wiring TerminalsRXBC605136254Remove the front panel from the boiler.Do not remove boiler loop.Replace the front panel ensuring a good seal is made.Connect the electrical plug.Pull out the mechanical timer.Push fit boiler control into housing.7 Power up the boiler and check the correct operation.Quick GuideRT510BCAlways isolate the AC Mains supply before installing or working on any componentsthat require 230 VAC 50Hz supply.RT510TX Button FunctionsIntroductionThe RT510TX thermostat will switch your heating system on or off, as needed, in accordancewith the time and temperature set by you. It can be used with the RXBC605 integral plug-in RFboiler control. The RF boiler control is a direct replacement for the basic time clock or blankingplate usually supplied with the boiler. Installing the RF boiler control takes minutes. Onceinstalled, you will benefit from all the control features of the RT510TX thermostat.868.0-868.6MHz; <13dBmSafety InformationUse in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnectyour device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, andinstallation must comply with the guidance, standards and regulations applicable to the city, country orstate where the product is installed. Failure to comply with the relevant standards could lead to prosecution.Product ComplianceThis product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity isavailable on www.saluslegal.com+HrSELECTSELECTSETSET+++Key Function1. Press once to activate Frost Mode2. Press for 3 seconds in order to activate Holiday ModePress once to activate/deactivate Boost functionPress once to enter/exit Permanent Override functionIncrease buttonDecrease buttonSelect the clock or programme settingsPress to confirm your settings1. Press once to enter/exit in Test Mode2. Press for 3 seconds to enter/exit Pairing ModePress the buttons for 3 seconds to enter Installer ModePress the buttons for 3 seconds to enter Clock SettingsBox contentQuick Guide 2 x AA AlkalineBatteries 2 x Fixing ScrewsRT510TX Desk StandRT510TX Dip Switch SettingsThe DIP Switches can be found on the rear of your thermostat.Control feature TPI SpanOperation When TPI is selected on DIPswitch № 2, the DIP switch№ 1 is functional. You canchoose the Cycles Per Hourbetween a lower comfortlevel (6CPH) and a highercomfort level (9CPH).When Span is selectedon DIP switch № 2,the DIP switch № 1 isnot functional. Thetemperature accuracy ofyour thermostat is set to± 0.25 °C.TEST / PAIRINGSELECT+HrSETTEST / PAIRINGSELECT+HrSET3 SecTEST / PAIRING+HrSELECT SET34Test the Pairing ProcessPairing ProcessOnce the LED stops flashing, press theTEST / PAIRING button for 3 sec.1 2Begin the pairing processEnd the pairing processiiiDuring test pairing, boiler control should flash confirming pair. If not, please followPairing Process.When enter test pairingmode, after a 10 minutecountdown the thermostatwill time out.Terminal Identifier Description1 N Neutral2 L Live input (230V AC)3 COM Common terminal (volt free)4 N.O. Normally OpenRXBC605 User ControlsRXBC605 Switch PositionLED - It will be on when the thermostat is demandingheat.Mode SwitchThe AUTO / MANUAL switch allows you to turn on theBoiler Control manually if required.SYNC Button - This is used only for pairing the RFcommunications.Press the SYNC button for 3seconds until LED starts flashing. The LG+5V is ready to be pairedwith your thermostat.3 Sec2. MANUAL mode. The usercan also move the switch to theMANUAL position; when in thismode, the boiler will be always turnedon and the LED indicator will alsobe lit constantly. The manual modeis only to be used as a temporarycontrol if problems develop with thecommunication from the thermostat.1. AUTO mode. When the switchon the Boiler Control is in the AUTO(normal) position, the Boiler Controlwill automatically receive the RF signalfrom the transmitter and control theboiler based on the programming ofthe transmitter. 1 2When the thermostat is operating inNORMAL mode, if the Boiler Control hasnot received a signal from the transmitterafter 1 hour, the Boiler Control will turnoff the boiler, and the LED indicator willflash constantly (two times every second).Once the Boiler Control receives a validON or OFF signal, the Boiler Control willcontrol the heating system accordingly.SALUS Controls plcSALUS HouseDodworth Business Park South,Whinby Road, Dodworth,Barnsley S75 3SP, UK.T: +44 (0) 1226 323961E: sales@salus-tech.comE: techsupport@salus-tech.comSALUS Controls is a member of the Computime Group.Maintaining a policy of continuous product development SALUS Controls plc reserve the right tochange specification, design and materials of products listed in this brochure without prior notice.www.salus-tech.comIssue Date: February 2018V005For PDF Installation guide please go to www.salus-manuals.comTEST / PAIRINGSELECT+HrSET3 SecRT510BC+ (Thermostat) Dip Switch SettingsTEST / PAIRINGSELECT+HrSETTEST / PAIRINGSELECT+HrSET3 SecTEST / PAIRING+HrSELECT SET34Test the Pairing ProcessPairing ProcessOnce the LED stops flashing, press theTEST / PAIRING button for 3 sec.1 2Begin the pairing processEnd the pairing processiiiDuring test pairing, boiler control should flash confirming pair. If not, please followPairing Process.When enter test pairingmode, after a 10 minutecountdown the thermostatwill time out.Terminal Identifier Description1 N Neutral2 L Live input (230V AC)3 COM Common terminal (volt free)4 N.O. Normally OpenRXBC605 User ControlsRXBC605 Switch PositionLED - It will be on when the thermostat is demandingheat.Mode SwitchThe AUTO / MANUAL switch allows you to turn on theBoiler Control manually if required.SYNC Button - This is used only for pairing the RFcommunications.Press the SYNC button for 3seconds until LED starts flashing. The LG+5V is ready to be pairedwith your thermostat.3 Sec2. MANUAL mode. The usercan also move the switch to theMANUAL position; when in thismode, the boiler will be always turnedon and the LED indicator will alsobe lit constantly. The manual modeis only to be used as a temporarycontrol if problems develop with thecommunication from the thermostat.1. AUTO mode. When the switchon the Boiler Control is in the AUTO(normal) position, the Boiler Controlwill automatically receive the RF signalfrom the transmitter and control theboiler based on the programming ofthe transmitter. 1 2When the thermostat is operating inNORMAL mode, if the Boiler Control hasnot received a signal from the transmitterafter 1 hour, the Boiler Control will turnoff the boiler, and the LED indicator willflash constantly (two times every second).Once the Boiler Control receives a validON or OFF signal, the Boiler Control willcontrol the heating system accordingly.SALUS Controls plcSALUS HouseDodworth Business Park South,Whinby Road, Dodworth,Barnsley S75 3SP, UK.T: +44 (0) 1226 323961E: sales@salus-tech.comE: techsupport@salus-tech.comSALUS Controls is a member of the Computime Group.Maintaining a policy of continuous product development SALUS Controls plc reserve the right tochange specification, design and materials of products listed in this brochure without prior notice.www.salus-tech.comIssue Date: February 2018V007For PDF Installation guide please go to www.salus-manuals.comTEST / PAIRINGSELECT+HrSET3 SecBoilerPLUSCOMPLIANTInternal TemperatureLoad CompensationITLCThe DIP Switches can be found on the rear of your thermostat. For all plug-inboiler receiver applications ensure SW1 is set to RAD.ON1 2ONNA SPANRAD ITLCControl feature ITLC SPANOperation ITLC Internal TemperatureLoad Compensation forimproved efficiency.When Span is selectedon DIP switch № 2, theDIP switch № 1 is notfunctional. |
Related manuals for Salus RT510BC+
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine