67Parameter name Parameter Values Description DefaultValuesMAXIMUM SETPOINT MAX SETPOINT FOR HEATINGMAX SETPOINT FOR COOLINGThis parameter allows to limit temperature setpoint range bysetting maximum setpoint for heating and cooling modes.Default temperature setting range: 5,5⁰C - 40⁰C35 ⁰CVALVE PROTECTION ONOFFValve protection function is intended to protect thermostaticvalves against getting stuck or jamming (e.g. in summer timewhen heating system is disabled). If thermostat doesn’t send asignal for heating for a period of 7 days, then heating is turnedon for a very short period of time just to move the actuators.ONINTERNAL RELAY DISABLEENABLERELAY TYPE NO-COM*RELAY TYPE NC-COM*If this option is disable then internal relay will not work at all.If this option is enable then relay will goes on if thermostat iscalling for heating or cooling.*parameter allows to set relay’s work mode**as default the relay is disable, but if you use SQ610 as astandalone device (device is not paired wirelessly with otherdevices) the relay is enableDISABLE**MINIMUM TURN-OFF TIME MIN OFF TIME FOR HEATINGMIN OFF TIME FOR COOLINGThis parameter specifies the minimum time between ON/OFFswitching in cooling mode. Thermostat have to wait this timevalue before it switches on again.Minimum Turn-Off time range: 0 - 999FORHEATING: 1FORCOOLING:180OPTIMISATION FEATURE OPTIMUM START ON / OFFOPTIMUM STOP ON / OFFOptimisation function is an energy-saving algorithm for effec-tive control of the heating device ensuring better temperaturecomfort at pre-defined times of the day.When the OPTIMUM START function is active, thermostatssends the heating signal to the heat source earlier so that thesetpoint temperature is reached at the time defined in theschedule.When the OPTIMUM STOP function is active, thermostat takesinto account the system inertia, switches off the heat sourceearlier to reach setpoint temperature at the time defined in theschedule.OPTIMUMSTART: OFFOPTIMUMSTOP: OFFCOMFORT WARM FLOOR DISABLELEVEL 1LEVEL 2LEVEL 3This function helps to keep the floor warm, even if the room iswarm enough and there is no need to turn on the heating. Usercan select 3 levels of warm floor feature.PLEASE NOTE: it is not an economy feature, as your heatingsystem may be ON even if there is no heating demand from theroom thermostat. It is COMFORT feature which keeps your floorwarm all the time. It is only for Heating Mode.DISABLEmodeONE TOUCH - this option is available only in ONLINE mode. Inthis scenario S1/S2 input is used to work with volt-free contact.By closing/opening S1/S2 contacts we can trigger any OneTouchrule created in the Smart Home application. More informationin chapter 6.15CHANGEOVER - an external volt-free contact is connected tothe S1/S2 input.When S1/S2 contacts are closed, thermostat works in heatingmode.When S1/S2 contacts are opened, thermostat works in coolingmode.This function is not available when thermostat is paired withKL08RF wiring centre, TRV head or RX10RF receiver.MINIMUM SETPOINT MIN SETPOINT FOR HEATINGMIN SETPOINT FOR COOLINGThis parameter allows to limit temperature setpoint range bysetting minimum setpoint for heating and cooling modes.Default temperature setting range: 5⁰C - 35⁰C5 ⁰C