58 | SAMLEX AMERICA INC.NOTES for Table 4.5:1. Values within brackets "( )" show the Default Setting.2. DEFAULT FREQ parameter is fixed al 60Hz for EVO-1212F / 1212F-HW and EVO-1224F/ 1224F-HW (Option 0=60Hz). If option 1 is entered, the screen line will show "!1=xxHz" meaning that Option 1 is invalid.3. Parameter "GEN MAX CURRENT" is not available for EVO-1212F / 1212F-HW andEVO-1224F / 1224F-HW as separate Generator input is not available in these models.4.5.2 Description of Parameters under Group 2 - INPUT SETTING4.5.2.1 DEFAULT FREQ (Table 4.5, Screen No. 1)Default frequency sets the Inverter frequency, which is also the standard frequency for AC input.Password 8052See Section 4.3.1S e l e c t G r o u p* C H A R G E C U R V E ðS e l e c t P a r a m e t e r* I N P U T S E T T I N G ðS e l e c t P a r a m e t e r* I N P U T S E T T I N GD E F A U L T F R E Q0 = 6 0 H zP a s s w o r d k e y i n0 0 0 0Down Key x 1 time Enter Key Enter KeyðS e l e c t P a r a m e t e r* I N P U T S E T T I N GD E F A U L T F R E Q0 = 6 0 H zNOTE: DEFAULT FREQ parameter is fixed al 60Hz for EVO-1212F / 1212F-HW andEVO-1224F / 1224F-HW (Option 0=60Hz). If option 1 is entered for thesemodels, the screen line will show "! 1=xxHz" meaning that Option 1 is invalid.4.5.2.2 GRID MAX CURRENT / GEN MAX CURRENT (Table 4.5, Screen Nos. 2 & 3)In Charging Mode, the net AC input current from the Grid/Generator is the sum of the ACside charging current and the pass through load current. Based on the rated capacity of theGrid Branch Circuit/Generator, the net AC input current will be required to be limited toprevent overloading of the Grid Branch Circuit/Generator.EVOTMSeries has a very powerful battery charger that will require a proportionate higher ACinput current from the Grid/Generator. The Grid Branch Circuit/Generator will also be requiredto provide current to the AC loads. The desired maximum value of input current from Grid/Generator can be programmed (Default setting is 20A for Models EVO-1212F / 1212F-HW/ 1224F / 1224F-HW and 30A for Models EVO-2212 / 3012 / 2224 / 4024). The EVOTMwillautomatically reduce charging current to support the AC loads on priority and use whatever isextra for charging. This will prevent overloading of the Grid Branch Circuit/Generator. If the ACinput current is over the setting value by 1A for 5 seconds, the EVOTMInverter/Charger will stopoutputting and display an error message “Input over current!” on LCD screen. For more details,please refer to Section 5.2.1 of the Owner's Manual for EvolutionTMSeries Inverter/Charger.SECTION 4 | Parameter SetupðEnter KeySee Table 4.5, Screen No. 1for programmable range