Setting an indoor unit address and installation optionThis unit hasa wireless signal receiver on the PCBallowingaddress and option setting programming with a wirelesscontroller.Set the indoor unit address and installation option with remotecontroller option. Set the each option separately since youcannot set the ADDRESS setting and indoor unit installationsetting options at the same time. You need to set twice whensetting indoor unit address and installation option. Addresscan also be set with service software or wired controllers.The procedure of option settingHigh Temp Button High Fan ButtonMode changeLow Temp Button Low Fan ButtonEntering mode foroption settingOption settingmodeStep 1. Entering mode to set option1. Remove batteries from the remote controller.2. Insert batteries while pressing High Temp button and Low temp button to enter the option setting mode.3. Check if you have entered the option setting status.Step 2. The procedure of option settingAfter entering the option setting status, select the option as listed below.Option setting is available from SEG1 to SEG 24• SEG1, SEG7, SEG13, SEG19 are not set as page option.• Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 On(SEG1~12) Off(SEG13~240 X X X X X 1 X X X X XSEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG242 X X X X X 3 X X X X XCAUTIONIR Receiver locationAHU PBAAM0**JNZDCH/AA IM ENG_V1.5_0708201533