Contents - indoor unit
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Precautions
- Precautions for Handling Refrigerant for Air Conditioner
- Product Specifications
- Accessory and Option Specifications
- Disassembly and Reassembly
- Indoor Unit
- BIG DUCT
- Global 4way Cassette type
- Duct type(Slim1,2)
- Duct type(Slim3)
- Duct type (MSP1)
- Duct type (MSP2, HSP SMALL)
- Duct type (MA1-Drain Pump Built-in)
- Duct type (MA2)
- AM036/048JNCDCH/AA
- CEILING
- Wall mounted type (Neo forte)
- Wall Mounted type (Boracay)
- Global Mini 4way
- AM145FNPDBH1
- AM290FNPDBH1
- Floor Standing Type (CONCEALED)
- Floor Standing Type (EXPOSED)
- OAP Duct type
- Global Duct 1 (AM007/009/012/015/018MNMDCH/AA)
- Global Duct 2,3 (AM024/027/030/036/048MNMDCH/AA)
- Troubleshooting
- Special Operation
- vacuum operation
- setting an indoor unit address and installation option
- option items
- What to check before diagnosis
- duct type
- ceiling type
- Number Display Method (Outdoor Unit, MCU, Cable remote control, wall-mount, etc.)
- Appropriate Measures for Different Symptom
- Main PCB has no power phenomenon
- Indoor Unit ROOM sensor Error (Open/Short)
- Indoor unit EVAP IN sensor Error (Open/Short)
- Indoor EVAP OUT sensor Error (Open/Short)
- Indoor Heat Exchanger's EVAP IN sensor dislocation error
- Indoor Heat Exchanger's EVA OUT sensor dislocation error (Open/Short)
- Simultaneous Indoor Heat Exchanger's EVA IN, OUT sensor dislocation error (Open/Short)
- Electronic Expansion Valve opening malfunction (2nd stage) -
- Detection of Floating Switch of Indoor Unit's Drain Pump
- The operational error of Indoor Unit's Fan Motor
- Mixed operation Error (Only applicable to Heat Pump Model/Not to HR model)
- EEPROM error
- Option error of the Remote Controller for an Indoor Unit
- Error due to incorrect Indoor Unit Power/Communication Cable Connection
- SPI Feedback Error
- Outdoor Unit Pipe Inspection Error
- Communication Error between Indoor and Outdoor Units during Tracking
- Communication Error between Indoor and Outdoor Units after Tracking
- Communication error between main and sub Unit of outdoor unit or between outdoor units
- Communication Error between MCU and Outdoor Unit
- Internal Communication error of the Outdoor Unit C-Box
- Internal PCB Communication error of the Outdoor Unit C-Box
- Communication Error between MCU and Outdoor Unit after Tracking is Completed
- MCU branch part setup error – inconsecutive connection with the use of 2 branch parts
- MCU branch part setup error – Repeated setup for the same address over 3 times
- MCU branch part setup error – non-installed address setup
- Setup Error for MCU Branch part – Setup Error for MCU Quantity Used
- MCU branch part setup error – Overlapping Indoor unit Address setup
- MCU branch part setup error – Set as being used without connection to an Indoor unit
- MCU branch part setup error – Connect an Indoor unit to a branch part not being used
- MCU branch part setup error – Connect more Indoor units than what is actually set up in MCU
- Outdoor Temperature Sensor Error
- Outdoor Temperature dislocation error
- Cond Out Temperature Sensor Error (Open/Short)
- Outdoor Cond Out sensor breakaway error
- Digital Compressor Discharge Temperature Sensor Error (OPEN/SHORT)
- Constant Rate Compressor Discharge Temperature Sensor Error (OPEN/SHORT)
- Compressor Discharge or Top 1/2 Temperature sensor error
- Dislocation error of Compressor SUMP Temperature (oil temperature) Sensor
- Suction Temperature sensor breakaway error
- SUMP Temperature Sensor Error (OPEN/SHORT)
- High Pressure sensor error (Open/Short)
- Low Pressure sensor error (Open/Short)
- Suction Temperature sensor error (Open/Short)
- Liquid Pipe Temperature sensor error (Open/Short)
- EVI In Temperature sensor error (Open/Short)
- EVI Out Temperature sensor error (Open/Short)
- Suction-2 Temperature Sensor Error (OPEN/SHORT)
- Comp. Down due to High Pressure Protection Control
- Comp. Down due to Low Pressure Protection Control
- Sump Sensor Error Due to Protection Control
- Comp. Down due to Compressor Discharge Temperature sensor
- phase Input Wiring error
- Comp. Down by Compression Ratio Control
- EVI EEV Open error
- Refrigerant Leakage Error
- Prohibition of the operation of Compressor due to Ooutdoor Temperature
- High Pressure Standard Not Met before Air Conditioning (Inability to Re-operate)
- CCH Malfunction and Sump Sensor Miswiring Error
- Fan starting error
- Fan lock error
- Momentary Blackout error
- Outdoor Fan Motor overheating
- Outdoor Unit Fan Motor RPM Error
- Fan IPM Overheat error
- Over-Voltage Error of an Outdoor Fan Motor
- Compressor Excess Current Error
- Compressor starting error
- Inverter Overcurrent error
- Overvoltage / Low voltage error
- DC Link voltage sensor error
- Liquid Compression Prevention Control
- Fan Motor Overcurrent error
- Input / Output Current sensor error
- Outdoor Fan PCB Overvoltage / Low voltage error
- Hall IC(Fan) error
- Inverter Overheat error
- Model mismatching of Indoor unit
- Breakdown of an EEV closure
- PCB Diagram and Parts List
- way cassette , mini 4way casette type
- Duct type (SLIM Duct 1,2)
- Duct type (Slim Duct 3, MA-1(Drain Pump Built-in)
- Duct type (MSP, HSP Small, BIG Duct, MA-2(Drain Pump Built-in)
- Celing type
- Big Ceiling
- Wall-Mounted type (Neo Forte)
- Wall-Mounted type (Boracay)
- Floor Stand Type
- OAP DUCT (AM✳✳✳JNESCH/AA)
- Global Duct -1,2 (AM007/009/012/015/018/024/027/030MNMDCH/AA)
- Global Duct -3 (AM036/048MNMDCH/AA)
- Wiring Diagram
- Slim 1way cassette type
- Big Ceiling (AM036/048JNCDCH/AA)
- RAC(Neo Forte)
- DUCT type (Slim Duct 3, MA-1(Drain Pump Built-in))
- DUCT type (Slim Duct 1,2, MSP)
- DUCT type (HSP Small , MA-2(Drain Pump Built-in))
- Global Duct (AM007/009/012/015/018/024/027/030MNMDCH/AA)
- Global Duct (AM036/048MNMDCH/AA)
- Reference Sheet
- Panel
- Pump-down Method
- How to Put Refrigerant in Refrigerant Container
|
Troubleshooting4-16 Samsung Electronics4-3-2 Option ItemsTYPE SAMSUNG MODELNUMBER StaticPressure Option Install Code Cycle code Install Code 2Slim 1WAY JSF-1AM007FN1DCH/AA - 017044-1180C8-201616-330010020010-100000-200000-300000030000-100000-200000-300000050000-100000-200000-300000AM009FN1DCH/AA - 017044-1180F8-201C1C-330010AM012FN1DCH/AA - 017044-11545D-202323-330010Mini 4WAY SmallAM009FNDNCH/AA - 01504F-19540A-201C1C-330000AM012FNDNCH/AA - 01504F-19342C-202323-330000AM018FNDNCH/AA - 01504F-19547F-203434-330000AM020FNDNCH/AA - 01504F-195591-203C3C-3300004WAYSmallAM009FN4DCH/AA - 014047-195064-201A1A-330000AM018FN4DCH/AA - 014047-195097-203434-330000AM024FN4DCH/AA - 014047-1950C7-204848-330000LargeAM030FN4DCH/AA - 014047-195409-205A5A-330020AM036FN4DCH/AA - 014047-19541B-206E6E-330020AM048FN4DCH/AA - 014047-19544F-209191-330020SLIM DUCTSlim1AM007FNLDCH/AA0 mmAq 010054-1254AE-201616-3311101 mmAq 010054-1255D1-201616-3311102 mmAq 010054-1255D1-201616-3311104 mmAq 010054-125904-201616-331110AM009FNLDCH/AA0 mmAq 010054-121913-201C1C-3311101 mmAq 010054-121946-201C1C-3311102 mmAq 010054-121946-201C1C-3311104 mmAq 010054-121979-201C1C-331110AM012FNLDCH/AA0 mmAq 010054-121946-202323-3311101 mmAq 010054-121979-202323-3311102 mmAq 010054-121979-202323-3311104 mmAq 010054-1219AC-202323-331110Slim2AM018FNLDCH/AA0 mmAq 010054-1259BA-203434-3311101 mmAq 010054-1259ED-203434-3311102 mmAq 010054-1259ED-203434-3311104 mmAq 010054-125E10-203434-331110AM024FNLDCH/AA0 mmAq 010054-125D2D-204848-3311101 mmAq 010054-125E50-204848-3311102 mmAq 010054-125E50-204848-3311104 mmAq 010054-125E83-204848-331110Slim3AM030FNLDCH/AA0 mmAq 010054-1B5915-205A5A-3311101 mmAq 010054-1B5948-205A5A-3311103 mmAq 010054-1B599F-205A5A-3311106 mmAq 010054-1B5AE4-205A5A-331110AM036FNLDCH/AA0 mmAq 010054-1B5956-206E6E-3311101 mmAq 010054-1B5989-206E6E-3311103 mmAq 010054-1B5AD0-206E6E-3311106 mmAq 010054-1B5E25-206E6E-331110AM048FNLDCH/AA0 mmAq 010054-1B59B9-209191-3311101 mmAq 010054-1B59EC-209191-3311103 mmAq 010054-1B5E33-209191-3311106 mmAq 010054-1B5E88-209191-331110MSP DUCTMSP-SAM018FNMDCH/AA0 mmAq 010054-125904-204747-3311102 mmAq 010054-125593-203434-3311104 mmAq 010054-1255C5-203434-3311106 mmAq 010054-1255F5-203434-3311108 mmAq 010054-125957-203434-331110AM024FNMDCH/AA0 mmAq 010054-125904-204848-3311102 mmAq 010054-125936-204848-3311104 mmAq 010054-125979-204848-3311106 mmAq 010054-125DF9-204848-3311108 mmAq 010054-125DFC-204848-331110MSP-1AM030FNMDCH/AA6 mmAq 010054-1259CE-205A5A-3311108 mmAq 010054-125E02-205A5A-33111010 mmAq 010054-125E46-205A5A-331110AM036FNMDCH/AA6 mmAq 010054-125E00-206E6E-3311108 mmAq 010054-125E44-206E6E-33111010 mmAq 010054-125E88-206E6E-331110MSP-2AM048FNMDCH/AA6 mmAq 010054-125E20-209191-3311108 mmAq 010054-125E43-209191-33111010 mmAq 010054-125E86-209191-331110AM054KNMDCH/AZ4 mmAq 010054-125E79-20A0A0-3311106 mmAq 010054-125EAA-20A0A0-3311108 mmAq 010054-125EDB-20A0A0-33111010 mmAq 010054-125EFC-20A0A0-33111012 mmAq 010054-125EFD-20A0A0-33111014 mmAq 010054-125EFE-20A0A0-331110 PreviousNext |