E-26Temperature and Humidity RangesOperating RecommendationsWhen you use your air conditioner, it is recommended that you read the following:Topic RecommendationHeating capacity The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors.If the temperature of the outside air drops, the air conditioner heats less. If the room is not warmenough, use an additional heating appliance.Warm air circulation The air conditioner circulates warm air to heat your room. It will take some time to warmthe air in your room entirely after the air conditioner turns on.Therefore, turn the air conditioner on in advance.Frost When you select the Heat mode, frost may form in the outdoor unit due to low temperatureand high humidity.If this happens: The heating operation is stopped. The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes,the air conditioner starts operating again normally.High indoor andoutdoor temperaturesIf both the indoor and outdoor temperatures are high when you select the Heat mode,the fan and the compressor of the outdoor unit may stop periodically.This is normal; wait until the air conditioner turns on again.Power failure If a power failure occurs when the air conditioner is operating, the air conditioner will turn off.When the power returns, the air conditioner will start up again automatically.Protection mechanism When the air conditioner is started immediately after being plugged in or stopped,the normal operation starts up after 3 minutes for the reason of protection.The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer tothe table for efficient use.MODE OPERATING CONDITIONS IF OUT OF CONDITIONSCOOLIndoor temp: 16°C~32°C - A safety device will stop continuously thesystem functioning;- Condensation may occur on the indoor unitwith risk to have either water blow off or dropson the floor;Indoor humidity: below 80%Outdoor temp: 21°C~43°CHEAT Indoor temp: below 27°C - A safety device will stop continuously thesystem functioning;Outdoor temp: 0°C~24°CDRYIndoor temp: 16°C~32°C - A safety device will stop continuously thesystem functioning;- Condensation may occur on the indoor unitwith risk to have either water blow off or dropson the floor;Indoor humidity: below 80%Outdoor temp: 18°C~43°CPOWER SUPPLY Single phase rated voltageminimum and maximum limit220V-240V~50Hz198V min.-264V max.Any damage occurs out of condition specified cannot be covered by product warranty.If the system works continuosly outside of conditions, its performace and reliability will be compromised.