73. Troubleshooting3-1 Items to be checked first1) The input voltage should be rating voltage ±10% range.The airconditioner may not operate properly if the voltage is out of this range.2) Is the link cable linking the indoor unit and the outdoor unit linked properly?The indoor unit and the outdoor unit shall be linked by 6 cables.Check the terminals if the indoor unit and outdoor unit are properly linked by the same number ofcables.Otherwise the airconditioner may not operate properly.3) When a problem occurs due to the contents illustrated in the table below it is a symptom not related tothe malfunction of the airconditioner.4) Indoor unit observes operation condition of the air conditioner, and displays self diagnosisdetails on the display panel.NO Operation of air conditioner1 The STD operation indication LED blinks when apower plug of the indoor unit is plugged in for the first time.2 In a COOL operation mode, the compressor does notoperate at a room temperature higher than the settingtemperature that the INDOOR FAN should operate.In a HEAT operation mode, the compressor does notoperate at a room temperature lower than the settingtemperature that indoor fan should operate.3 Fan speed setting is not allowed in AUTO or DRY mode.4 Compressor stops operation intermittently in DRY mode.5 Compressor of the outdoor unit is operating although it isturned off in a HEAT mode.6 Timer LED only of the indoor unit lights up and theair conditioner does not operate.7 The compressor and indoor fan stop intermittently in HEATmode.8 Indoor fan and outdoor fan stop operation intermittently ina HEAT mode.9 The compressor stops intermittently in a COOL mode or DRYmode, and fan speed of the indoor unit decreases.It indicates power is on. The LED stops blinking if the operationON/OFF button on the remote control unit is pushed.In happens after a delay of 3 minutes when the compressor is reop-erated. The same phenomenon occurs when a power is on.As a phenomenon that the compressor is reoperated after a delay of3 minutes, the indoor fan is adjusted automatically with referenceto a temperature of the air blew.The speed of the indoor fan is set to LL in DRY mode.Fan speed is 5 steps is selected automatically in AUTO mode.Compressor operation is controlled automatically in DRY modedepending on the room temperature and humidity.When the unit is turned off while de-ice is activated, the compressorcontinues operation for up to 9 minutes (maximum) until the deice iscompleted.Timer is being activated and the unit is in ready mode.The unit operates normally if the timer operation is cancelled.The compressor and indoor fan stop intermittently if room tempera-ture exceeds a setting temperature in order to protect the compres-sor from overheated air in a HEAT mode.The compressor operates in a reverse cycle to remove exterior ice ina HEAT mode, and indoor fan and outdoor fan do not operate inter-mittently for within 20% of the total heater operationThe compressor stops intermittently or the fan speed of the indoorunit decreases to prevent inside/outside air frozen depending on theinside/outside air temperature.ExplanationNO Display1 STD LED blinking (1Hz)2 TIMER LED blinking (1Hz)3 STD and TIMER LED blinking (1Hz)4 NATURE LED blinking (1Hz)Restore from power failure (input initial power)Indoor unit Room sensor Error (open or short)Indoor unit heat exchanger temperature sensor Error (open or short)Indoor fan malfunctioning (for spead is Below 450rpm)Self Diagnosis