2 . Open the cover panel.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.(Refer to the picture below)• Each wire is labeled with the corresponding terminal number.5 . Pass the other end of the cable through the 65 mm hole in the wall.6 . Close the connector cover by tightening the screw carefully.7 . Close the cover panel.8 . Remove the terminal board cover on the side of the outdoor unit.9. Connect the cables to the terminals as seen in the picture.• Each wire is labeled with the corresponding terminal number.Indoor unitOutdoor unit• Also circular terminal must be matched with screw size in terminal block.• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.• Please ensure that Power & Communication cables are separated, they must not be in the same cable.10. Connect the grounding conductor to the grounding terminals.11. Close the terminal board cover by tightening the screw carefully.• In Russia and Europe, consult with the supply authority to determine the supply system impedance beforeinstallation.• Connect the wires firmly so that wires can not be pulled out easily.(If they are loose, it could cause burn-out of the wires.)• Connect the wires according to color codes, referring to the wiring diagram.• The power cable and the interconnection cable should be selected according to the specification in page 12.1(L) 2(N) F1 F21(L) 2(N) F1 F2L N F1 F2Indoor unitOutdoor unitEnglish-13A3050 EU_IM_DB68-04212A_HP_EN.indd 13 2013-10-23 16:31:13