7Samsung Electronics3-2 Controls and Components3-2-1 Thermostat OFFWhen the room temperature is lowered by the air condition-er, the gas within the thermostat will contract and cause abreak in the electric contact. The compressor will then stop.After the compressor stops, the room temperature will rise ONAs the room temperature increases to a selected level,the gas within the thermostat expands, causing electriccontact, which provides the source of electric power to thecompressor. The room temperature will fall and the cycle willrepeat.3-2-1 Thermostat Control OperationBy turning the control knob clockwise(toward highernumbers), the temperatures will be cooler.By turning the control knob counterclockwise (toward lowernumbers), the temperature will be warmer.Level 01 : Cool air will be supplied above 30~35˚Level 10 : Cool air will be ceased below 28~32.5˚Level 10 : Cool air will be supplied above 17.4~20.4˚Level 10 : Cool air will be ceased below 14.4~17.4˚Operating modeselection dialTemperaturecontrol dialAir flow blade swing switchAll manuals and user guides at all-guides.com