E-35ENGLISHTroubleshootingDetection of errorsLED Display on the receiver & display unitLED DisplayAbnormal conditionsIndicatorsRemarksConcealed TypeGreen RedStandard TypePower reset X X X XError of temperature sensorin the indoor unit (Open/Short) X X X XError of heat exchanger sensorin the indoor unit X X XError of the outdoor temperature sensorError of the condensor temperature sensorError of the discharge temperature sensorX X X1. No communication for 2 minutesbetween indoor units(Communication error for more than 2 minutes)2. Indoor unit receiving thecommunication error from outdoor unit3. Outdoor unit tracking 3 minutes error4. When sending the communicationerror from the outdoor unit, themismatching of the communicationnumbers and installed numbers aftercompletion of tracking.(Communication error for more than 2 minutes)X X X1. Indoor unit error(Display is unrelated withoperation)2. Outdoor unit error(Display is unrelated withoperation) If you turn off the air conditioner when the LED is flickering, the LED is also turned off.On Flickering X Off If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED. If you re-operate the air conditioner, it operates normally at first, then detect an error again.Air Marketing Group LLC141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-1782 Fax: 201-782-1783 Web: www.amgair.com Email: info@amgair.com