Feature & Operation77Samsung Electronics6-1-6 Energy saving operation control In case of Cooling Only model The Energy saving mode is applicable to only in both the COOL mode and AUTO mode. In case of Heat Pump model The Energy saving mode is applicable to only in the COOL mode. Energy saving operation specification- If you select the Energy saving mode during automatic operation, the setting temperature(Ts) will be fixed to "the standardvalue +2°C"(26°C).- If you select the Energy saving mode during cooling operation, you may set the room temperature from "26°C to 30°C",but if you hope to control the room temperature below 26°C in the Energy saving mode, the room temperature will be com-pelled to be 26°C.- If you select the Energy saving mode, the up/down louver will enter the "Swing" status.- OPERATION PATTERN A : In the Energy saving mode when Room Temperature(Tr) equals to the Setting Temperature(Ts) or over.- OPERATION PATTERN B : In the Energy saving mode when Room Temperature(Tr) is below the Setting Temperature(Ts).Tg +ßTgTemperatureEnergy savingmodeGeneral operation modeEnergy saving mode startingTs+1TsOFFONTimeCOMP_orTg +ßTg +ßTgTg←Tg+αTg←Tg+αTemperatureEnergy savingmodeGeneral operationmodeEnergy savingmode startingEnergy savingpattern mode BChange the Energy savingpattern A.Energy saving Ts+1Energy saving TsTrTsOFFONTimeCOMP_or