OfficeServ 7100 INSTALLATIONTECHNICAL MANUAL PART 8 JULY 20108.26) The RUN LED of the MP10 card lights green and the MC LED flashes when the systemnormally starts the booting process.7) Once the booting is complete, the RUN LED of the MP10 card flashes green, and the MCLED stops flashing and remains lit. (It takes approximately 2 ½ to 3 minutes to boot up).8) Enable MGI channels by entering the appropriate license key in system programming (ifMGI services are required).If the MP10 MMC+/SD card is not detectedIf the system cannot detect the MP10 MMC+/SD card, the MC LED might not light orflash. In such cases, turn off the power, replace the MP10 MMC+/SD card and turn thepower on again. If the MP10 MMC+/SD card is still not detected, turn off the powerand replace the MP10.9) Check if the LED status of other interface cards is normal.If the LED status of the MP10, or interface card is abnormal, turn off system powerand turn the power on again.8.2b STARTING THE SYSTEM (MP10a)It is required to clear memory and start with a default database when using the new MP10acard. The MP10a card no longer has a battery switch to clear memory. The system memory iscleared to default by the performing the following procedure:1) Check if the cards and cables are properly mounted and connected to the OfficeServ7100 cabinet.2) Make sure the MP10a SD Card with system software is in the Media slot.3) To start the MP10a from default (Clear memory): Power up the system and wait for 3minutes for the system to boot.4) Press and hold the RST (reset) switch on the front of the MP10a card for approximately 7to 10 seconds (this will default the database).5) The RUN LED will change from GREEN to AMBER and will stop flashing after 10 seconds.Release the RST switch and wait for system to complete the boot up process. Check theLEDs of the MP10a.6) The RUN LED of the MP10a card lights green and the MC LED flashes when the systemnormally starts the booting process.7) Once the booting is complete, the RUN LED of the MP10a card flashes green, and theMC LED stops flashing and remains lit (approximately 3 minutes).8) When the system completes the boot up process, the system memory is cleared and thedatabase is at default.9) Enable MGI channels by entering the appropriate license key in system programming (ifMGI services are required).10) Test system for normal operation.