35Operation Function2) Water Supply function2-1) When the ice tray is leveled again after ejecting ice, the water solenoid value will be controlled to supply water bytime check basis. (See the “Time to supply water” Table)3) Ice production3-1) After 90 minutes pass from the water supply, the control board will check the temperature.3-2) If the sensor reads the temperature lower than -7℃ for more than 5 minutes, than the ice production process iscompleted.4) Test function In order to operate a test function, press the knob (Test Switch) for 1.5 second. This function can be used to check a proper working, to clean the ice tray, and to adjust the water level in the ice tray.4-1) This function only works when the ice tray is leveled and the ice full signal is cleared.4-2) When the water line is connected, each process such as a water supply, ejection, and leveling, can be investigatedby this button.5) Ice off function5-1) When the Ice off option is selected by Ice Type button, the ice making process will cease.5-2) When the ice making process ceases, the final state will be the ice tray with the supplied water.5-3) When Cubed or Crushed option is selected again, the control board will check an accummlated time period. Aftermaking it 90 minutes and when the ice tray temperature is acceptable, ice ejection process will begin.6) Functions when the freezer door is open When the freeze door is open, all ice maker related processes will cease in order to minimize noise and to prevent icefrom dispensing.6-1) The ice tray stops moving regardless of the position.6-2) The water supply process remains working as usual.6-3) If the ice tray is in the middle of ice ejecting process, close the freezer for 30 seconds and check if the tray isleveled. If it is not leveled, it must be out of order.1) A defrost is determined based on the accumulated compressor on-time.2) When the power is engaged for the first time, the defrost cycle for the freezer and the refrigerator will begin after 4hours of the accumulated compressor on-time.3) A defrost interval depends on the ambient temperature, the number of door openings, and the door open time.4) A minimum interval is 6 hours and a maximum is 8 hours for the refrigerator, and 12 hours and 16 hours for thefreezer, respectively.5) The defrost heater on-time is determined by the defrost sensors as follow :9-10) Defrost FunctionFreezerBelow 10℃Refrigerator17℃Heater ONHeater OFF-10℃