ENGLISHE-21If you have used more than 5m(7.5m), add “Q” of refrigerant for extra meter.(For maximum piping length and height, refer to page 15)The quantity of additional refrigerant is variable according to the installationsituation. Thus, make sure the outdoor unit situation before addingrefrigerant. This operation can only be performed by a qualified refrigerationspecialist.How to Calculate the Quantity of Adding RefrigerantOUTDOOR INDOOR "Q" (R410A)UH140GAMC CH140EAMC 70g/mUH105GAMC CH105EAMC 70g/mImportant information regulation regarding therefrigerant used Refrigerant type GWP valueR410A 1975 GWP=Global Warming PotentialThis product contains fluorinated greenhouse gases covered by the KyotoProtocol. Do not vent gases into the atmosphere.Please fill in with indelible ink,- the factory refrigerant charge of the product,- the additional refrigerant amount charged in the field and- + the total refrigerant charge.on the refrigerant charge label supplied with the product. The filled-out label must be adhered in the proximity of the productcharging port (e.g. onto the inside of the stop valve cover).Indoor unitOutdoor unit= ( ) kg= ( ) kg += ( ) kgContains fluorinated greenhouse gasescovered by the Kyoto Protocol.Note a. Factory refrigerant charge of the product: see unit name plateb. Additional refrigerant amount charged in the field(Refer to the above information for the quantity of refrigerantreplenishment.)c. Total refrigerant charged. Refrigerant cylinder and manifold for chargingab cd