E-31ENGLISHFixing the Installation PlateBefore fixing the installation plate to a wall or window frame, youmust determine the position of the 65mm( inch) hole throughwhich the cable, piping and hose pass to connect the indoor unit upto the outdoor unit. When facing the air conditioner in position onthe wall, the piping and cable can be connected from the: Right Left Rear (right or left)1 Determine the position of the pipe and drain hose hole using the rightfigure and drill the hole with an inner diameter of 65mm( inch) so that itslants slightly downwards.2 If you are fixing the indoor unit to a... Then follow Steps...Wall 3.Window frame 4 to 6.3 Fix the installation plate to the wall in a manner appropriate to the weightof the indoor unit.➢ If you are mounting the plate on a concrete wall with anchor bolts, theanchor bolts must not project by more than 20mm( inch).4 Determine the positions of the wooden uprights to be attached to thewindow frame.5 Attach the wooden uprights to the window frame in a manner appropriateto the weight of the indoor unit.6 Using tapped screws, attach the installation plate to the wooden uprights,as illustrated in the last figure opposite.INSTALLING THE INDOOR U NIT2 916342 91634.5(1 )38650Pipe Hole(2 )916(1 )34.5 38(2 )64.5 916( )19.5 34(6 )156 18 (14 )364 516(2 )67 58410~730 16 ~18 28 34( )Installation plateUnit : mm(inch)Unit : mm(inch)Unit : mm(inch)