CW-6000/6100/6200 Series3Thank you for using the machine from GUANGZHOU TEYUELECTROMECHANICAL CO., LTD. Please read the installation instructionscarefully before installing and operating and keep it properly.This installation instructions is not a quality assurance. GUANGZHOU TEYUELECTROMECHANICAL CO., LTD reserves the right to the interpretation ofcorrection of typographical errors, improper mentioned information and productimprovement. The amended content will be reprinted in installation instructionswithout notice in advance.<1> Cautions1. Please ensure that the power supply and electrical outlet are in good contactand the earth wire must be firmly grounded!2. Please make sure there is stable and normal voltage for the working chiller!As the refrigeration compressor is more sensitive to the power supply andvoltage, so the operating voltage of our standard product is of 200 ~ 250V (110Vmodel is of 100 ~130V). If you do need a wider operating voltage range,customization is available for us.3. Unmatched power frequency can cause the chiller damage!Please choose model of 50Hz or 60Hz according to actual circumstance.4. To protect the pump, it’s strictly forbidden to run the chiller without water in thestorage water tank!The new machine is packed after draining whole water in the tank, so pleasemake sure the tank has water inside before machine starting, otherwise it’seasily to have the pump damaged. When the water level is below the green(NORMAL) range of the water level gauge, the cooling capacity of our chillerwill go down slightly. Hence please ensure the water level is within the green(NORMAL) range. To drain through circulating pump is strictly prohibited!5. Please be sure that the air inlet and air outlet are in good ventilation!There must be at least 50cm from obstructions to the air outlet which is in theback of the cooler, and should leave at least 30cm between obstructions andthe side air inlet.6. The filter screen must be regularly cleaned!It’s essential to unpick and wash the dust gauze, or the serious blockage willcause breakdown to the chiller.7. Please pay attention to the effect of the condensate water!With greater ambient humidity, when the water temperature is lower than theambient temperature, the condensate water will generate on the surface ofwater circular pipes and the cooled components. If above circumstanceappears, it is recommended to set a higher water temperature or keep pipesand cooled parts warm.8. This product is an industrial equipment.For professional use only.