PLC-HF10000L Basic Serial Command Functional Specifications8/236.4 Operation RequirementsWhen the projector is in the status below, Functional Execution Commands are limited.(Status Read Commands are available in following status)Projector Status Available Functional Execution CommandsIn Standby status C00: POWER ONCount Down in process C00: POWER ON (Countdown is terminated)Cooling Down in process NONE (No Execution)Cooling Down in process due to abnormaltemperature NONE (No Execution)In Abnormal Temperature NONE (No Execution)In Abnormal Power Status NONE (No Execution)On switching modes NONE (No Execution)Power Saving Cooling Down in process NONE (No Execution)In Power Saving status C00: POWER ONC01: POWER OFFNote) In the above status, it returns [ACK] [CR] even if the projector receives other commands,6.5 POWER ON CommandCOMMAND “C00” [CR]DetailPower ONWhen already Power is ON, no operation starts.When sending this command during Count Down in process, Count Downprocess is terminated.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.6 POWER OFF Command (Immediate POWER OFF)COMMAND “C01” [CR]DetailPower OFF (Standby)When Power is turned OFF with ON/STAND-BY button of the projector andremote control, “Power OFF” is displayed. In contrast, this command executesimmediately Power OFF.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.7 INPUT 1 CommandCOMMAND “C05” [CR]Detail Select Input 1Note) When there is no board inserted to Input 1, it is not executed.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]