-87-Chassis Descriptionerror error code error Infomation(See Powe Failure Detection System) error code error Infomation(See Powe Failure Detection System)Normal 0 -Power Failure1000 AV, AV 1016 MAIN, FAN51001 AV, LAN 1017 MAIN, FAN61002 MAIN, AD 1018 MAIN, FAN71003 MAIN, SI 1019 ERR, PRESSURE1004 MAIN, F-FPGA 1020 ERR, FIL_DET1005 MAIN, 5V 1021 ERR, FIL_MTR1006 MAIN, PIC 1022 ERR, SHUT_MTR1007 MAIN, 25V1008 MAIN, KEYSTONE1009 MAIN, GAMMA1010 MAIN, 9V1011 MAIN, S12V1012 MAIN, FAN11013 MAIN, FAN21014 MAIN, FAN31015 MAIN, FAN4Temperature Error2000 Sensor A detects abnormal temperature. (IC1816)2001 Sensor A fails measurement. (IC1816)2100 Sensor B detects abnormal temperature. (IC1814)2101 Sensor B fails measurement. (IC1814)2102 Sensors B-A temperature error.2200 Sensor C detects abnormal temperature. (IC1692)2201 Sensor C fails measurement. (IC1692)2202 Sensors C-A temperature error.Lamp Error3000 Lamp1 fails on3001 Lamp1 goes out3002 Communication Error on Lamp1System Error 4000 FPGASW, CONFIGShutter Error 5000 SHUTTER, ERRORFilter Error 6000 Filter cloggedError History LogThis projector provides the error history log function. Tocheck the logs, you need to enter the service mode andselect Group No. "220" and Item No. "0" to "49". The errorcode is displayed on the Data column. The description ofthe error code is listed on the table below.* How to enter the service mode and select the group, itemand data value, see "Service Adjustment Menu Opera-tion".GroupNo.ItemNo.Data(Error Code)220 0123::49✻ <- Latest Error✻✻✻::✻How to reset the error History Log1. Enter the Service Mode, and select Group No. "220" and Item No. "50".2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".* How to enter the service mode and select the group, item and data value, see "Service Adjustment menu operation".