-13-30 ECO_TEMP_FAN1_MAX 48/84 Control End Temperature for for FAN1 at Eco Mode SVGA/XGA31 ECOTEMP_FAN2_MIN 41/47 0~255 Control Start Temperature for FAN2 at Eco Mode SVGA/XGA32 ECO_TEMP_FAN2_MAX 48/54 Control End Temperature for for FAN2 at Eco Mode SVGA/XGA333435 ECO_VALU_FAN1_MIN 70/70 Minimum Control Value for FAN1 at Eco Mode36 ECO_VALU_FAN1_MAX 135/135 Maximum Control Value for FAN1 at Eco Mode37 ECO_VALU_FAN2_MIN 85/85 0~255 Minimum Control Value for FAN2 at Eco Mode38 ECO_VALU_FAN2_MAX 130/130 Maximum Control Value for FAN2 at Eco Mode394041 HINOR_TEMP_FAN1_MIN 41/48 Control Start Temperature for FAN1 at Highland Normal Mode42 HINOR_TEMP_FAN1_MAX 48/54 Control End Temperature for FAN1 at Highland Normal Mode43 HINOR_TEMP_FAN2_MIN 41/48 0~255 Control Start Temperature for FAN2 at Highland Normal Mode44 HINOR_TEMP_FAN2_MAX 48/54 Control End Temperature for FAN2 at Highland Normal Mode454647 HINOR_VALU_FAN1_MIN 80/80 Minimum Control Value for FAN1 at Highland Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)48 HINOR_VALU_FAN1_MAX 135/135 Maximum Control Value for FAN1 at Highland Normal Mode49 HINOR_VALU_FAN2_MIN 95/100 0~255 Minimum Control Value for FAN2 at Highland Normal Mode50 HINOR_VALU_FAN2_MAX 135/135 Maximum Control Value for FAN2 at Highland Normal Mode515253 HIECO_TEMP_FAN1_MIN 41/47 Control Start Temperature for FAN1 at Highland Eco Mode54 HIECO_TEMP_FAN1_MAX 48/54 Control End Temperature for FAN1 at Highland Eco Mode55 HIECOTEMP_FAN2_MIN 41/47 0~255 Control Start Temperature for FAN2 at Highland Eco Mode56 HIECO_TEMP_FAN2_MAX 48/54 Control End Temperature for FAN2 at Highland Eco Mode575859 HIECO_VALU_FAN1_MIN 70/70 Minimum Control Value for FAN1 at Highland Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)60 HIECO_VALU_FAN1_MAX 135/135 Maximum Control Value for FAN1 at Highland Eco Mode61 HIECO_VALU_FAN2_MIN 85/85 0~255 Minimum Control Value for FAN2 at Highland Eco Mode62 HIECO_VALU_FAN2_MAX 130/130 Maximum Control Value for FAN2 at Highland Eco Mode636465 CLNOR_TEMP_FAN1_MIN 41/48 Control Start Temperature for FAN1 at Ceiling Normal Mode66 ClNOR_TEMP_FAN1_MAX 48/54 Control End Temperature for FAN1 at Ceiling Normal Mode67 CLNOR_TEMP_FAN2_MIN 41/48 0~255 Control Start Temperature for FAN2 at Ceiling Normal Mode68 CLNOR_TEMP_FAN2_MAX 48/41 Control End Temperature for FAN2 at Ceiling Normal Mode697071 CLNOR_VALU_FAN1_MIN 80/80 Minimum Control Value for FAN1 at Ceiling Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)72 CLNOR_VALU_FAN1_MAX 135/135 Maximum Control Value for FAN1 at Ceiling Normal Mode73 CLNOR_VALU_FAN2_MIN 95/100 0~255 Minimum Control Value for FAN2 at Ceiling Normal Mode74 CLNOR_VALU_FAN2_MAX 135/135 Maximum Control Value for FAN2 at Ceiling Normal Mode757677 CLECO_TEMP_FAN1_MIN 41/47 Control Start Temperature for FAN1 at Ceiling Eco Mode78 CLECO_TEMP_FAN1_MAX 48/54 Control End Temperature for FAN1 at Ceiling Eco Mode79 CLECOTEMP_FAN2_MIN 41/47 0~255 Control Start Temperature for FAN2 at Ceiling Eco Mode80 CLECO_TEMP_FAN2_MAX 48/54 Control End Temperature for FAN2 at Ceiling Eco Mode818283 CLECO_VALU_FAN1_MIN 70/70 Minimum Control Value for FAN1 at Ceiling Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)84 CLECO_VALU_FAN1_MAX 135/135 Maximum Control Value for FAN1 at Ceiling Eco Mode85 CLECO_VALU_FAN2_MIN 85/85 0~255 Minimum Control Value for FAN2 at Ceiling Eco Mode86 CLECO_VALU_FAN2_MAX 130/130 Maximum Control Value for FAN2 at Ceiling Eco Mode878889 FAN1_ADJUST_VOLT_MIN 1 DAC Adjustment Value at minimum driving voltage for FAN1 ✻ Fan Control Adjustment90 FAN1_ADJUST_VOLT_MAX 230 DAC Adjustment Value at maximum driving voltage for FAN1 ✻ Fan Control Adjustment91 FAN2_ADJUST_VOLT_MIN 1 0~255 DAC Adjustment Value at minimum driving voltage for FAN2 ✻ Fan Control Adjustment92 FAN2_ADJUST_VOLT_MAX 230 DAC Adjustment Value at maximum driving voltage for FAN2 ✻ Fan Control Adjustment9394Group: 112 PC Real/ AV Cinema0 PC Real Contrast 32 0 ~ 631 PC Real Brightness 32 0 ~ 632 PC Real Red 34 0 ~ 633 PC Real Green 32 0 ~ 634 PC Real Blue 31 0 ~ 635 PC Real Gamma 8 0 ~ 156 AV Cinema Contrast 32 0 ~ 637 AV Cinema Brightness 32 0 ~ 638 AV Cinema Color 32 0 ~ 639 AV Cinema Tint 32 0 ~ 6310 AV Cinema Red 32 0 ~ 6311 AV Cinema Green 30 0 ~ 6312 AV Cinema Blue 29 0 ~ 6313 AV Cinema Sharpness 8 0 ~ 3114 AV Cinema Gamma 8 0 ~ 1515 AV Cinema N.R. 1 0 ~ 216 AV Cinema PROGRESSIVE 1 0 or 1No. Adjustment Item Initial Value Range Input source / DescriptionElectrical Adjustments |
Related manuals for Sanyo PLC-SL20
manualsdatabase
Your AI-powered manual search engine