PLC-WTC500L Basic Serial Command Functional Specifications14/256.29 ON START SET CommandCommand “C28” [CR]DetailEnable Power ON StartThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]6.30 ON START CANCEL CommandCommand “C29” [CR]DetailDisable Power ON StartThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]6.31 POWER MANAGEMENT READY CommandCommand “C2A” [CR]DetailSet Power Management function to ready statusThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]6.32 POWER MANAGEMENT CANCEL CommandCommand “C2B” [CR]DetailSet Power Management function to off statusThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]6.33 POWER MANAGEMENT SHUTDOWN CommandCommand “C2E” [CR]DetailSet Power Management function to Shutdown mode.This status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]6.34 D.ZOOM + CommandCommand “C30” [CR]Detail Enter Digital Zoom mode and expand image sizeThis command works the same way as “D.ZOOM ” button of the remote control.Response Acceptable [ACK] [CR]Unacceptable “?” [CR]