-38-Electrical AdjustmentsGroup/Item Item Name Function Initial Range Note7 ANGLE 2 COUNT 5 1 - 108 BLIND SECTOR 1 160 0 - 10249 BLIND SECTOR 3 32 0 - 102410 BLIND SECTOR BIAS 61 0 - 1024Group 200 Option0 Logo Prohibition (Forced No Brand) Logo Prohibition (0: Menu, 1: Forced, 2:China, 3-9: not used) 0 0 - 2 Effective after AC On1 RS232C Baudrate Baud Rate 0 0 - 2 0: 19200bps, 1: 9600bps, 2: 115200bps2 PJLink Enable PJLink 0 0 - 1 0:Disable 1:Enable3 Shipping Setting 0 0 - 20 Default set when the value is set to 104 CABLE SW Long Cable 0 0 - 10 0: Disable, 1: Enable5 PW Debug Command Enable 0 0 - 1 0:Disable (Sanyo Serial Command Eanble)1: Enable (PW Debug Mode)6 Device Refresh Disable 0 0 - 1 0:Enable, 1:DisableNo last memory7 Device Access Disable 0 0 - 1 0:Enable (Normal), 1:DisableNo last memory20 Projector Time Reset 0 0 - 20 Projector Time is cleared when the value isset to 1021 Lamp Warning Time (NORMAL) Lamp Life at Normal Mode (Warning Time atNormal) 500 - 800022 Lamp Warning Time (ECO) Lamp Life at Eco Mode (Warning Time atEco) 500 - 800023 Lamp Warning Time (HIGH) Lamp Life at High Mode (Warning Time atHigh) 500 - 800030 Lamp life test enable 0:Disable 1:Enable, for safety test only31 Lmap On time(for life test) For test purpose32 Lamp Off time(for life test) For test purpose33 Lamp total time(for life test) For test purpose40 PreScaler n/a 0-255 n/a41 Htime n/a 0-65535 n/a52 Lamp Counter reset Times Reset Times of Lamp Counter n/a 0 - 255 Read only54 Factory Default Execute Times Reset times of Fanctory Default n/a 0 - 255 Read only55 Motor Disable 0: On, 1: Off n/a 0 - 156 Menu Position Move menu (X asis) 0 0 - 102457 Menu Position Move menu (Y asis) 0 0 - 102458 Lamp Go Out n/a 0 - 1Group 201 Option (signal)0 FrameLock Option 1 0 - 1 0: FrameLockOFF at PC signal1: FrameLockON at PC signal and 47Hz(Vfreq) ~ Panel frequency of input signal2 Field Sense Invert Enable 0 0 - 1Reverse Processing of FLDINVSetting Value0: Disable - Used FLDINV Setting Value1: Enable - Used Reversed FLDINV SettingValue34 Sub Image Enable 1 0 - 1 0:Disable (Service Adjustment Dsiable,Used all the Center Values1:Enable (Service Adjustment Enable)6 Zoom Accelerator Enable 0 0 - 1 0:Zoom Accelerator OFF,1:Zoom Accelerator ONNo last memory7 DZoom Reset by Keystone 0 0 - 1 0:Enable (Normal), 1:Disable (Dzoo is notcancelled even if Keystone is cancelled)No last memory8 Stability Count Count Value of V-missing 5 0 - 2559 Sensivity for Signal Lost (HSYNC) Only used this value for No SignalJudgement(Hz) 350 0 - 6553510 Sensivity for Signal Lost (VSYNC) Only used this value for No SignalJudgement(Line) 3 0 - 25511 Keystone Filter Center Value Reference Value 16 0 - 30Group 202 Option (MCI model only)0 Memory Viewer OSD Memory Viewer OSD Display (1: Yes, 0: No) 1 0 - 1Group 210 LampContorl0 DIMMER_CTRL_LEVEL1 Luminance Level 1 Data for Dimmer: DimLevel 1 at the less than the Value 0 - 255 Philips 200W1 DIMMER_CTRL_LEVEL2 Luminance Level 2 Data for Dimmer: DimLevel 2 at the less than the Value 0 - 2552 DIMMER_CTRL_LEVEL3 Luminance Level 3 Data for Dimmer: DimLevel 3 at the less than the Value 0 - 2553 DIMMER_CTRL_LEVEL4 Luminance Level 4 Data for Dimmer: DimLevel 4 at the less than the Value 0 - 255