PLC-XU300/350 Basic Serial Command Specifications15/236.34. ON START Setting CommandCommand “C28” [CR]Detail Enable Power ON Start.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.35. ON START Cancel CommandCommand “C29” [CR]Detail Disable Power ON Start.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.36. Power Management Ready CommandCommand “C2A” [CR]Detail Set Power Management to Ready mode.This status is stored in EEPROM and retained regardless of Power ON/OFF.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.37. Power Management OFF CommandCommand “C2B” [CR]Detail Set Power Management to OFF mode.This status is stored in EEPROM and retained regardless of Power ON/OFF.ResponseAcceptable [ACK] [CR]Unacceptable “ ”[CR]6.38. Power Management Shut down CommandCommand “C2E” [CR]Detail Set Power Management to Shut down mode.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.39. D.ZOOM + CommandCommand “C30” [CR]Detail Enter Digital Zoom mode and expand image size.This command works the same way as “D.ZOOM ▲” button of the remote control.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]