-58-TroubleshootingNo Powerlamp cover switchMake sure that the lamp cover is mounted correctly. Ifnot or the lamp cover removed, the lamp does not lighton for the safety. Check the lamp cover and lamp coverswitch (SW901).- When all of led indicators are not lighting, the symptom indicates that the primary power supply circuit doesnot operate properly. Check the power primary circuit and parts as follow;AC cord, F601 (Fuse), Power board,SW90 (Thermal sw.) short in normalSW90 opens when the surrounding temperature of the switch exceeds 100°C.This projector provides a function which can be specified a defective area simply by indicating the LEDs. Connect theAC cord and press the Power button once and then check the LED indication.- When the WArNING (red) and PoWer (red) indicators are flashing, the symptom indicates that the projec-tor detected an abnormal temperature risen inside the projector. Check the air filters and remove the object nearthe intake and exhaust fan openings, and wait until the POWER indicator stops flashing, and then try to turn onthe projector.The internal temperature is monitored by sensor ICs, IC8831, IC881 on the Main board and IC8811 on theR/C board.- When the WArNING indicator lights red, the symptom indicates that the projector detected an abnormality inthe cooling fan operation or in the power supply secondary circuits. Check fan operation and power supply lines,and the driving signal status.The P_FAIL signal (Error: L) is sent to pin 15 of IC301 when the abnormality occurredinside the projector, and then the IC301 sends the shutdown signal, LAMP_DC_ON, to the power supply circuitto stop its operation, and signal BLAST_AC to the lamp ballast board via IC4891 and SW901to stop operation of the lamp circuit.An abnormality occurs on the secondary power supply;Check power supplies S16V, S6V, S-7V. P_FAIL signal becomes “Low” when the abnormality occurs onany of the power supply lines.An abnormality occurs on the fan control circuit;Check FN901, FN90, FN903, FN904, FN905, FN906 and peripheral circuit.If any of the fans has an error, the fan lock signal drives Q3601 becomes "High". As the result, signalFAN_ERR becomes Low and is sent to lamp ballast board to stop lamp circuit.An abnormality occurs on the drive signals;ON_15V signal (Power-on: H) is output from pin 01 of IC301 and switches IC59,15.5VL supply circuit,ON_5V signal (Power-on: H) is output from pin 110 of IC301 and switches IC554,IC5081, 11-AMP supplycircuit, ON_3.3V signal (Power-on: H) is output from pin 11 of IC301 and switches IC561, 1.0V and Q3583.3V supply circuit.LAMP_DC_ON signal (Power-on: H) is output from pin 89 of IC301 and supplied to the P.C Control IC,IC61, on the power supply board through Q651, and PC661.BLAST_AC signal (Power-on: H) is output from pin 84 of IC301 and applied to pin of IC4891 and outputpin 4 and then supplied to the lamp ballast board through SW901.LAMP_DET signal at the pin 85 of IC301 is applied from the lamp ballast unit. If the abnormality occurredon the lamp ballast unit, LAMP_DET signal becomes “High” and then IC301 shuts down the power supplycircuit.