-9-Lamp ReplacementLamp replacementWArNING:- For continued safety, replace with a lamp assembly of the sametype.- Allow the projector to cool for at least 45 minutes before you open thelamp cover. The inside of the projector can become very hot.- Do not drop the lamp module or touch the glass bulb! The glass canshatter and cause injury.WArNING : turN oFF tHe uV lAMP BeFore oPeNING tHe lAMP coVer.uSe uV rAdIAtIoN eYe ANd SKIN ProtectIoN durING SerVIcING.Note- The projector cannot be turned-on with lamp cover removed, becausewhen the lamp cover is removed, the lamp cover switch is also re-leased to switch off the lamp circuit.Unplug the AC power cord. Let the projector cool for at least 45minutes.Loosen the three (3) screws that secure the lamp. Lift the lampout of the projector by using the handles.13Replace the lamp with a new one and secure the three (3)screws. Make sure that the lamp is set properly. Push thelamp cover and secure the screw.4Loosen the screw and open the lamp cover.2Connect the AC power cord to the projector and turn on theprojector.5ProcedureFor continued safety, replace with a lamp of thesame type. Do not drop a lamp or touch a glass bulb!The glass can shatter and may cause injury.Allow a projector to cool for at least 45 minutesbefore you open the Lamp Cover. The inside of theprojector can become very hot.cAutIoNcAutIoNcAutIoNWhen replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may bebroken.If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that thelamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp covergently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyesor mouth, seek medical advice immediately.order rePlAceMeNt lAMPtype No. PoA-lMP131Service Parts No. 610 343 2069Lamp ScrewHandlesScrewScrewScrewLamp Cover