– 16 –3-6. Adjust Specifications[CP1 board (Side B)]Note:1. Frequency adjustment can be carried out in through imagemode.1. IC501 Oscillation Frequency AdjustmentAdjustment method:1. Adjust with VR501 to 510.6 ± 1 kHz.2. Lens Data AdjustmentPreparation:POWER switch: ONAdjustment method:1. Double-click on the DscCalDi.exe.2. Select “Lens Data” in the LCD “Test”.3. Type in the value given on the bar code that is attached tothe back of the lens into the blank space next to “PI switch”in the Lens data dialog box.The first digit of the bar code value is a “0” or a “1”.4. Type in the value given on the bar code that is attached tothe surface of the lens into the blank space next to “DeltaSB” in the Lens data dialog box.However, for lenses that have a blank line instead of a barcode, type in “202020”.The first digit of the bar code value is a “2” or a “3”.5. Click “Set” at the right side of Lens data Dialog box.3. Lens AdjustmentPreparation:POWER switch: ONAdjustment condition:More than A3 size siemens star chartFluorescent light illumination with no flickerIllumination above the subject should be 400 lux ± 10 %.Adjustment method:1. Set the siemens star chart 150 cm ± 3 cm so that it be-comes center of the screen.2. Double-click on the DscCalDi.exe.3. Click the Focus, and click the Yes.4. Lens adjustment value will appear on the screen.(When adjustment is failed, “NG: X” will display.)5. Click the OK.Measuring PointADJ. LocationMeasuring EquipmentADJ. ValueCL511Frequency counterVR501510.6 ± 1 kHzCL511VR501Camera Approx.150 cm 3 cmSiemensstar chartDscCalDi xOKFocus ResultNG:!