– 20 –7. LCD Panel Adjustment[VF1 board (Side B)]7-1. LCD RGB Offset AdjustmentPreparation:POWER switch: ONAdjusting method:1. Double-click on the DscCalDi.exe.2. Adjust LCD “RGB Even” so that the amplitude of the CL423waveform is 1.0 V ± 0.05 V.3. Adjust LCD “RGB Odd” so that the amplitude of the CL423waveform is 4.5 V ± 0.05 V.7-2. LCD Gain AdjustmentAdjusting method:1. Adjust LCD “RGB Gain” so that the amplitude of the CL423waveform is 1.55 V ± 0.05 Vp-p.Note:7-1. LCD RGB Offset adjustment should always be carriedout first.CL423 waveform1.55 V± 0.05 Vp-pCL423 waveform4.5 ±0.05 V1.0 ± 0.05 V 0 V (GND)CL4233-7. Factory Code Setting1. Check the "Factory Code" display within the Setting group.2. For U.S.A., Canada and NTSC general areaIf "FC_SANYO_U" does not appear, click on the " " marklocated on the right of the "Factory Code" display BOX andselect "FC_SANYO_U".3. For Europe and PAL general areaIf "FC_SANYO_EX" does not appear, click on the " " marklocated on the right of the "Factory Code" display BOX andselect "FC_SANYO_EX".3-8. Language Setting1. Click on the " " mark located on the right of the"Language" display BOX.2. Select language. (Default is English.)3. End "DscCal" and remove the camera before turning thecamera power OFF.FirmwareDataAWBFocusUV MatrixRGB OddRGB GainTintRGB EvenVCOMDCPhaseLCDCalibration UploadInitializeLCD Type H AFC TestVCOMPP(LOW)VCOMPP(HI)Cal DataCal ModeOKOKEVFUSB storageGetSetVID SetPID SetSerial SetRev. SetSettingLanguageVideo ModeVCOFactory CodeHall Cal.Backrush pulse : SetGet