– 18 –3-7. Adjust Specifications1. Lens AdjustmentPreparation:POWER switch: ONIf using a ready-made collimator, set to infinity.Note:Do not vibrate during the adjustment.Adjustment method:1. Set the camera 0 cm from the collimator. (Do not enter anylight.)2. Set the camera so that it becomes center of the screen inthe collimator.3. Double-click on the DscCalDi.exe.4. Click the Focus, and click the Yes.5. Lens adjustment value will appear on the screen.6. Click the OK.Adjustment value determination is effectuated using below val-ues.The adjustment values fulfill the conditions below, they are de-termined as within specifications.Adjustment value determinationPZ_SW: PSWPSW: adjustment value of zoom PR switch position(945<=PSW+PBR<=1010)PZ_BR: PBRPBR: adjustment value of zoom backrush pulse(0<=PBR<=45)PZ_SP: PSPPSP: adjustment value of zoom stowing pulse(210<=PSP<=320)AF_SW: ASWASW: adjustment value of focus PI switch position(893<=ASW<=985)AF_BR: ABRABR: adjustment value of focus backrush pulse(0<=ABR<=12)CameraCollimator3-6. The adjustment item which in necessary in part exchangeCOMPL PWB CP-1LensAdjustmentAWBAdjustmentCCD White PointDefect DetectAdjustmentCCD Black PointAnd White PointDefect DetectAdjustment InLightedFactoryCordSettingUSB storageinformationregistrationLanguageSettingCOMPL PWB TB-1COMPL PWB TB-2ResetSetting: Be sure to carry out the necessary adjustments after replacing the unit.: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.LENS ASSYDscCalDi xOKFocus ResultPZ_SW: 950PZ_BR: 19PZ_SP: 260AF_SW: 937AF_BR: 3AF_WIDE: 11AF_MID1: -7AF_MID2: -22AF_MID3: -20AF_TELE: -17!