– 15 –Preparation:POWER switch: ONAdjusting method:1. When setting the camera in place, set it to an angle so thatnothing appears in any part of the color viewer except thewhite section. (Do not enter any light.)2. Double-click on the DscCalDi.exe.3. Click the AWB, and click the Yes.4. AWB adjustment value will appear on the screen.5. Click the OK.Adjustment value determination is effectuated using the 2ndline "AGC", 5th line "CHECK" and 6th line "MS" values.If AGC=A1, A2, A3, A4, A5 and CHECK=W1, W2, W3 andMS=MS1, MS2 and the adjustment values fulfill the conditionsbelow, they are determined as within specifications.A1< 1023, A2 < 1023, A3 < 1023, A4 < 1023,A5 < 1023W1 = 128 ± 2, W2 = 128 ± 2, W3 = 130 ± 403400 <= MS1 <= 4850, 3800 <= MS2 <= 52504. CCD White Point Defect Detect AdjustmentPreparation:POWER switch: ONAdjustment method:1. Double-click on the DscCalDi.exe.2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.3. After the adjustment is completed, OK will display.4. Click the OK.5. CCD Black Point And White Point Defect DetectAdjustment In LightedPreparation:POWER switch: ONSetting of pattern box:Color temperature: 3100 ± 20 (K)Luminance: 900 ± 20 (cd/m2)Adjusting method:1. Set the camera 0 cm from the pattern box. (Do not enterany light.)2. Double-click on the DscCalDi.exe.3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.4. After the adjustment is completed, the number of defectwill appear.CameraPattern box(color viewer)