3. ELECTRICAL ADJUSTMENT3-1. Table for Servicing ToolsNote: J-1 color viewer is 100 - 110 VAC only.J-2 Siemens star chart is the same as before models.3-2. Equipment1. Oscilloscope2. Digital voltmeter3. AC adaptor4. IBM R -compatible PC5. DC regulated power supply3-3. Adjustment Items and Order1. IC501 Frequency Adjustment2. 5.0 V (D) Voltage Adjustment3. 3.3 V (D) Voltage Adjustment4. 12.4 V (L) Voltage Adjustment 15. 12.4 V (L) Voltage Adjustment 26. 5.8 V (L) Voltage Adjustment7. CCD Defect Defect Adjustment8. AWB Adjustment9. Flange-back Adjustment10. LCD Panel Adjustment10-1. LCD H AFC Adjustment10-2. LCD RGB Offset Adjustment10-3. LCD Gain Adjustment10-4. LCD Blue Brightness Adjustment10-5. LCD Red Brightness Adjustment3-4. Setup1. System requirementsWindows 95 or 98IBM R -compatible PC with 486 or higher processorCD-ROM drive3.5-inch high-density diskette driveSerial port with standard RS-232C interface8 MB RAMHard disk drive with at least 15 MB availableVGA or SVGA monitor with at least 256-color display2. Installing calibration software1. Insert the calibration software installation diskette into yourdiskette drive.2. Open the explorer.3. Copy the DSC Cal folder on the floppy disk in the FD driveto a folder on the hard disk.3. Color ViewerTurn on the switch and wait for 30 minutes for aging to takeplace before using Color Pure.4.Computer screen during adjustmentRef. No. Name Part codeJ-1J-2J-3VJ8-0007VJ8-0166Color viewer 5,100 KSiemens star chartCalibration softwareJ-1 J-2J-3FirmwareImageAWBFocusUV MatrixR BrightRGB OffsetTintB BrightGainPhaseFirmware Version:LCDCalibration UploadInitializeLCD Type H AFC TestVCOMDCVCOMPPJ-4J-4 VJ8-0151Extension cord