Factory Test & Alignment Specification For MT56 Series (V1.0)93.3 Other MenuThe Other Menu contains some TV basic information, with which we can check the TV setting beforeproduction.3.4 Service MenuService Menu contains some basic information of the device, such as Project ID, Hardware, Softwareversion, USB Update etc. This menu is especially useful for after-sale service.Other MenuName Default DescriptionTestPattern > Switch the TV source into test pattern, and restarting TV is the only way to excit.UartEnable OFFThe switch of VGA serial port information.The item must be disabled (OFF) after production.DeviceID .. Show the device id of TV.MAC .. Show the MAC address of TV.HuanID .. Show the Huan id of TV.ClientType .. Show the Client type information.Service MenuName Default DescriptionProject ID 1 Select project parameters, depending on the BOM description.Hardware MT5655 mainboard ChassisSoftware V8-MT56551-LF1V003 version number of Main SoftwareBootloader XXX version number of bootcoreUSB Update.. Update the software by USB disk,detailed description see Appendix 2 “Software Update”