Factory Alignment Specification of normal SIACPPage 8 of 12Each panel has it’s own colour coordinates, Please refer to the following table.㪛㫐㫅㪸㫄㫀㪺㪆㪎㪇㩼㩷㪮 L32V6200/L32E5200 L42E5200F/L42V6200F C32E320/L32P60 C42E320F/L42P60Fx y x y x y x yNormal 0.275 0.310 0.275 0.290 0.280 0.290 0.280 0.290Cool 0.265 0.285 0.265 0.290 0.270 0.280 0.270 0.280Warm 0.305 0.330 0.305 0.330 0.312 0.330 0.320 0.320 Expected Targets and TolerancesThe measured parameters should be “x, y” coordinates.The White Balance alignment should be performed using a contact less analyzer (ei: MinoltaCA-210). The analyzer may not touch the screen surface, and measurement must be performed in adark environment keeping the probe(s) at 90+/-2° from the panel.The result should measure up the relevant spec.2.4 High Pot. and Insulating Resistance TestsAt the end of the process, a High Pot. and an Insulating Resistance tests are required formatching Safety Electrical requirements (ei: xxxx) High Voltage Withstanding requirements- “Voltage” Ö 3500 VAC- “Max Leakage Current” Ö 10 mA- “Test Time” Ö 5 sec Insulating Resistance requirements- “Voltage” Ö DC500V- “Threshold Min” Ö 4M¡- “Test Time” Ö 3 sec3.FactorydefaultsettingsDo the “Reset shop” before packing.The detail of reset shop follow OOB setting.“Factory Menu” Definition1)ˊ HotkeyItem Sub-item Value NoteHotkey Off/On OFFġhotkey is invalidON ġhotkey(Return key) is availability2)ˊBurning Mode