3383532002 Rev C2.14. J1 ConnectorJ1-1 ENA_IN Enable/Disable Dry Contact with J1-14 (ENA_OUT)J1-2 IF_COM Isolated Interface Common. Return for SO, PS_OK, and optional IEEE interface.J1-3 IF_COM Isolated Interface Common. Return for SO, PS_OK, and optional IEEE interface.J1-4 N/CJ1-5 N/CJ1-6 N/CJ1-7 N/CJ1-8 LOC/REM Input for selecting between Local or Remote Analog programming.J1-9 VPGM Input for Remote Analog voltage/resistance programming of the Output VoltageJ1-10 IPGM Input for Remote Analog voltage/resistance programming of the Output CurrentJ1-11 VMON Output Voltage MonitorJ1-12 COM Control Common for VMON & IMON, CV/CC, LOC/REM signal and P (2-WireParallel method only).Connected internally to the negative local sense (-LS)J1-13 CV/CC Output for Constant Voltage / Constant Current mode indicationJ1-14 ENA_OUT Enable/Disable Dry Contact with J1-1 (ENA-IN)J1-15 SO Input for Shut-Off control of the power supply output.J1-16 PS_OK Output for indication of the power supply statusJ1-17 N/CJ1-18 N/CJ1-19 N/CJ1-20 N/CJ1-21 LOC/REM Signal Output for indicating if the unit is in Local or Remote Analog programming mode.J1-22 VPGM_RTN Return for VPGM J1-9; connected to negative local sense (-LS).J1-23 IPGM_RTN Return for IPGM J1-10; connected to negative local sense (-LS).J1-24 IMON Output for Current MonitorJ1-25 P Output for Current Balance in Parallel Option (all methods)