Tanita BC-420MA Instruction Manual
When necessary(cautions for safety)When necessary(cautions for safety)GBGB49DXA was originally designed to measure bone mineral content, but inthe full-body scan mode the body fat percentage, fat mass, and fat freemass of individual body parts (arms, legs, trunk) can also be measured.The image below shows one example of body compositionmeasurement results obtained by DXA.- What is the DXA method?- What is the visceral fat?48- Principles of body composition measurementTechnical notesBody composition measurement by the BIA method.IntroductionThis equipment provides estimated values for each measured value of body fat percentage, fat mass,fatfree mass, muscle mass and bone mass by the DXA method, estimated value for the total body watermeasured value by the dilution method and estimated value for the visceral fat rating by MRI methodusing the Bioelectrical Impedance Analysis (BIA method).For measurement, a mode must be selected based on body type.1) Standard (for 5-99 years of age)2) Athletic (for Athletic persons who exercise considerably more than non-athlete)Making a distinction by body type in the measurement mode produces more reliable body compositionmeasurements for athletic persons, whose body compositions differ from those of average persons.BIA is a means of measuring body composition – fat mass, predicted muscle mass, etc. – by measuringbioelectrical impedance in the body. Fat within the body allows almost no electricity to pass through, whileelectricity passes rather easily through water, much of which is found in muscles. The degree of difficultywith which electricity passes through a substance is known as the electrical resistance, and the percentageof fat and other body constituents can be inferred from measurements of this resistance.The Tanita Body Composition Analyzer measures body composition using a constant current source with ahigh frequency current (50kHz, 90μA). The 8 electrodes are positioned so that electric current is suppliedfrom the electrodes on the tips of the toes of both feet, and voltage is measured on the heel of both feet. Thecurrent flows into the upper limbs or lower limbs, depending on the body part(s) to be measured.Visceral adipose tissue (VAT) is fat that accumulates in the abdominal cavity and around internal organs.VAT is said to be more likely to cause lifestyle-related diseases than subcutaneous adipose tissue (SCAT).Accordingly, knowing and periodically checking the VAT accumulation risk serves as an important guidein the prevention of lifestyle-related diseases.Tanita has developed the technology for measuring the VAT accumulation risk through bioelectricalimpedance analysis (BIA) in comparison with image analysis applied to magnetic resonance imaging(MRI), in addition to the established technology for measuring the percent of body fat. The VATaccumulation risk is calculated by estimating the VAT area by the BIA method on the basis of MRI imageprocessing. This method has a higher correlation than the estimation of the VAT accumulation risk basedon BMI or abdominal circumference (waist circumference), allowing estimation that corresponds moreprecisely to individuals.* The VAT area by MRI is calculated by carrying out an image processing of the cross section of the lumbervertebra L4-L5 regions.(Fig. 1 - Fig. 3: Research results by N. Y. Columbia University and Jikei University Published by the NorthAmerican Association for the Study of Obesity [NAASO] in 2004.)- What is dilution method?In the dilution method, a labeled substance for a known amount is given and the concentration inequilibrium diffusing evenly is measured to obtain the total amount of the solvent that dilutes the labeledsubstance.To measure the total body water (TBW), deuterium oxide (D2O) is generally used as the labeled substance.Deuterium oxide uses the overall total body water as dilution space so the total body water can beobtained. To obtain the extracellular fluid amount, sodium bromide (NaBr) is used as a labeled substance.Bromine (Br) is said to not enter the inside of cells, and uses extracellular fluid as the dilution space.Body composition measurement resultsobtained by DXA (Lunar Co., Ltd; DPX-L) |
Related manuals for Tanita BC-420MA
Tanita BC-402 Instruction Manual
Tanita BC-401 Instruction Manual
Tanita BC-G03 Instruction Manual
Tanita BC-732 Instruction Manual
Tanita BC-601 Instruction Manual
Tanita BC-350 Instruction Manual
Tanita BC-731 Instruction Manual
Tanita BC-718 Instruction Manual
Tanita BC-601F Instruction Manual
Tanita BC-577F Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine