Operator's Manual Fifth Edition • Fifth PrintingWork Area Safety8 GS™-30 • GS™-32 • GS™-46 Part No. 114313GTWork Area SafetyElectrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Obey all local andgovernmentalregulations regardingrequired clearance fromelectrical power lines. Ata minimum, the requiredclearance contained inthe chart below must befollowed.Line Voltage Required Clearance0 to 50KV 3.05 m50 to 200KV 4.60 m200 to 350KV 6.10 m350 to 500KV 7.62 m500 to 750KV 10.67 m750 to 1000KV 13.72 mAllow for platform movement, electrical line sway orsag, and beware of strong or gusty winds.Keep away from themachine if it contactsenergized power lines.Personnel on the groundor in the platform must nottouch or operate themachine until energizedpower lines are shut off.Do not operate the machine during lightning orstorms.Do not use the machine as a ground for welding.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity or themaximum platform capacity of the platformextension.Models without capacity indicator:Maximum capacityGS-1530 and GS-1532 272 kgGS-1930 and GS-1932 227 kgGS-2032 363 kgGS-2632 227 kgGS-3232 227 kgGS-2046 544 kgGS-2646 454 kgGS-3246 318 kgModels with capacity indicator:The maximum capacity varies with the height of theplatform.Maximum capacity - GS-1530 and GS-1532Height of platform Maximum capacity4.6 m 272 kg4 m 390 kg2.8 m 484 kg1.6 m 390 kg1 m 344 kgMaximum capacity - GS-1930 and GS-1932Height of platform Maximum capacity5.8 m 227 kg5.2 m 320 kg3.7 m 435 kg1.6 m 320 kg1 m 227 kg