GB/IE/NI21Introduction / Safety notesPlease note: Cannot be used to jump - start6 V batteries.z Parts description1 Digital display button2 Battery type button3 Charge start button4 "–" pole connection cable (black)5 "+" pole connection cable (red)6 Digital display7 Mains cable8 Fuse with coverz Technical specificationsInput voltage: 230 V~ 50 HzReturn current*: < 5 mA (no ACinput)Nominal output voltage: 6 V/12 VCharge current: 2 A, 6 A,15 A ± 10%Battery type with: 12 V/6 V and8 - 210 AhcapacityHousing protection type: IP 20* = Return current means the current that thecharger consumes from the battery whenno mains current is connected.Please note: The maximum charge currentdepends closely on the internal resistance ofthe connected battery. This internal resistanceis determined by factors such as age, capaci-ty and the type of the connected battery.z Delivery contentsCheck the scope of delivery and the deviceas well as all parts for damage right afterunpacking. Do not take a defective unit orparts into operation.1 Charger Ultimate Speed ULG 15 B42 Quick contact connection terminals(1 red, 1 black)1 original operating instructionsz Safety notesKEEP OUT OF THE REACHOF CHILDREN! DANGER! Avoid danger tolife and danger of injury fromimproper use! CAUTION! Do not operatethe device with a damagedcable, mains cable or mainsplug. Damaged mains cablespose danger to life from elec-tric shock. Have the mains cable onlyrepaired by authorized andtrained specialists if there isany damage! Contact the ser-vice point of your country ifyou need any repair! DANGER OF ELEC-TRIC SHOCK! Ensurethat the vehicle is not in opera-tion if the battery is installedfirmly in the vehicle! Switch offthe ignition and put the vehicleinto the parking position, withthe parking brake engaged(e.g. car) or the rope attached(e.g. electric boat)!