-9.4.4 Write SR176 Card’s Block DataFunction Description:Write data to specify SR176 card’s block.Function Call:INT32 RDINT_SR176WriteBlock(BYTE u8COMPort, BYTE u8BlkNo, LPBYTE pu8Data);Parameter:u8COMPort: The reader’s COM port number (1 – 255)u8BlkNo: The block number which user wants to read (Ex: 0, 1, 2…).pu8Data: The data which user wants to write to the block.Return code:Please refer to section 9.5.9.4.5 Lock SR176 BlockFunction Description:Lock the specify block on SR176 card.Function Call:INT32 RDINT_SR176LockBlock(BYTE u8COMPort, BYTE u8BlkNo);Parameter:u8COMPort: The reader’s COM port number (1 – 255)u8BlkNo: The block number which user wants to lock (Ex: 0, 1, 2…).Return code:Please refer to section 9.5.9.4.6 Read SRIX4K Card’s Block DataFunction Description:Read the block from specify SRIX4K card.Function Call:INT32 RDINT_SRIX4KReadBlock (BYTE u8COMPort, BYTE u8BlkNo, LPBYTE pu8Data);Parameter:u8COMPort: The reader’s COM port number (1 – 255)u8BlkNo: The block number which user wants to read (Ex: 0, 1, 2…).pu8Data: Receive the data.Return code:Please refer to section 9.5.9.4.7 Write SRIX4K Card’s Block DataFunction Description:Write data to specify SRIX4K card’s block.Function Call:INT32 RDINT_SR176WriteBlock(BYTE u8COMPort, BYTE u8BlkNo, LPBYTE pu8Data);Parameter:u8COMPort: The reader’s COM port number (1 – 255)u8BlkNo: The block number which user wants to read (Ex: 0, 1, 2…).pu8Data: The data which user wants to write to the block.Return code:Please refer to section 9.5.